4.5
ENGINE OPERATION
Power Selector Switch
The power selector switch functions to direct electrical power to
the desired control station. With the switch in the ground posi-
tion, power is supplied to the emergency stop switch at the
ground control station. When the switch is in the platform posi-
tion, power is supplied to the emergency stop switch at the plat-
form control station. The switch should be in the off position
when parking the machine overnight.
Emergency Stop Switch
This switch, when in the on (out) position, provides electrical
power to the ground controls or platform controls, as applicable.
In addition, the switch can be used to turn off power (push the
switch IN) to the function controls in the event of an emergency.
31215865
SECTION 4 - MACHINE OPERATION
Starting Procedure
NOTE:
Initial starting should always be performed from the Ground
Control Station.
1.
Check engine oil before attempting to start engine; if neces-
sary, add oil in accordance with Engine Manufacturers Man-
ual.
2.
Pull out the red EMERGENCY STOP switch (ON).
3.
Position the PLATFORM/GROUND SELECT switch to the
desired operating control station (PLATFORM or GROUND).
4.
If operating a dual fuel machine, place the LPG/GASOLINE
SELECT switch to the desired position.
NOTE:
If the LPG system is selected, ensure that the hand valve on the
LPG supply tank is opened prior to attempting to start the
engine.
4-3