Precor TRM700-16 Base Service Manual page 145

Experience series 700 line
Hide thumbs Also See for TRM700-16 Base:
Table of Contents

Advertisement

If the unit power does not switch "ON" or trips the circuit breaker, see . Troubleshooting
o
Tripped Breakers ,
If the console does not power up, see Troubleshooting Console Power.
o
Verify that the console is operating correctly
Run the Display, and Keypad diagnostic tests (see
(51765761)" on
page 21). Resolve any failures.
Note: Keep in mind that if a key on the keypad does not function, the lower control
module will not receive a user initiated request for action. For failed keys problems,
the cause for the failure would not be in the lower PCA or the unit base and no error
codes will be logged.
Review the Error Log or
Always review the Error Log or CPA Event Log when troubleshooting an issue. The error logs
will contain any triggered error code events and related information. You can then refer to
Error Code Troubleshooting Guide
tomer service for assistance, refer to the Error Log or CPA Event Log for additional inform-
ation to help the representative resolve the issue.
Refer to the
Error Code Troubleshooting Guide
mation.
IMPORTANT: Error Code description and Troubleshooting information is contained in
the Error Code Troubleshooting Guide , see
Note: Not all failures trigger an error event code. Many issues are purely mechanical
in nature and therefore cannot trigger an error event code.
Verify (reproduce) the issue.
Operate the unit in normal user mode to verify if the reported failure can be reproduced. Is this
a repeatable or intermittent type failure. Make note of any additional observations (noises,
vibrations, etc.) that occur at the time of the failure which may help resolve the issue.
Note:  It is important to keep in mind that some issues are weight (load) related. You
may need to increase the exerciser weight to reproduce the failure.
Perform hardware validation diagnostic tests
Access the Hardware Validation Diagnostic Tests service mode and run any related tests that
might help isolate the cause of the issue, see
(51765761)" on
page 21. These tests will help identify good and failed components. Resolve
any resulting failures.
Verify Club settings
1
Control Processing Assembly
Experience Series 700 Line Treadmills
1
CPA
Event Log for any active error codes
to help resolve the issue. Also, when calling Precor cus-
"Hardware Validation Service Mode
"Hardware Validation Service Mode
for error code descriptions and repair infro-
Error Code
Guide.pdf.
6    Troubleshooting