3. Remove the four #3 Phillips fasteners and remove the Power Entry Assembly bracket
. Hold the bracket while removing to prevent wire cable damage. Retain fastener
hardware for installation.
4. Disconnect the two brown wire input power connections (or two brown and two blue
wire connections for the 240 Vac option) on the ON/OFF SW Circuit Breaker
on
page 75.
5. Remove the two #2 Phillips fasteners and remove the ON/OFF SW Circuit Breaker
Retain fastener hardware for installation.
Installation Instructions
1. Reinstall the ON/OFF SW Circuit Breaker
fasteners.
2. Reconnect the two brown input power wires (or two brown and two blue for the 240 Vac
option) on the ON/OFF SW Circuit Breaker
3. Reinstall the Power Entry Assembly bracket
fasteners. Make sure that the wire cables are not pinched or damaged during install-
ation.
4. Reinstall the hood cover, see
5. Connect the power cord and switch the ON/OFF SW Circuit Breaker ON.
6. Do the Operation Verification tests (see
to service.
Experience Series 700 Line Treadmills
and secure using the two #2 Phillips
, see
and secure using the four #3 Phillips
"Hood Cover Replacement" on
"Operation Verification" on
5 Replacement Procedures
ON/OFF SW Circuit Breaker Replacement
"" on
page 75.
page 56.
page 15) and return