2. Reconnect the motor static bleed resistor ground wire and secure using the 5/16 " hex
head fastener. Fully tighten the fastener to ensure good electrical contact with the frame
weldment.
WARNING: Static electric shock hazard. Make sure the motor static bleed resistor
ground wire is secruly connected to the frame. When the ground wire is not con-
nected, touching the motor housing could cause static charge electrical shock and
personal injury.
3. Reconnect the Motor Controller "MTH" and "MOTOR" cable connectors , see
Controller (MC) Replacement" on
correct orientation and alignment before inserting into the MC
1
Input and Output Interface.
Experience Series 700 Line Treadmills
page 84. Make sure the cable connectors have the
5 Replacement Procedures
Drive Motor Replacement
"Motor
1
I/O
connector.