15.
Press the Rack Release Lever and turn the Rack so that the screw securing the Laser (PH)
Unit to the chassis can be accessed through the hole [12] in the metal cross plate.
16.
Remove three screws [12] and the Laser (PH) Unit [13].

Precautions for Reinstallation of the Laser (PH) Unit

Warning:
When reinstalling the Laser (PH) Unit, make sure that you insert the lever [14] of
the Laser (PH) shutter into the lever of the machine [15].
Note:
Reconnect the blue connector (S5) before you reinstall the cover onto the printer.
To reinstall the ribbon cable, loosen the lower tab on the plastic air duct to give access
to the route.

Paper Take-Up Unit

1.
Remove the Rear Cover. See
2.
Remove the Right Cover. See
3.
Remove the Left Cover. See
4.
Remove the High Voltage Unit. See
Phaser® 6120 Color Laser Printer Service Manual
[13]
[12]
[12]
4139fs2037c2
[14]
[15]
4139fs2539c0
Rear Cover
on page 5-4.
Right Cover
on page 5-6.
Left Cover
on page 5-5.
High Voltage Unit (HV)
5-23
Disassembly/Assembly Procedures