7.
When the Transfer Roller is replaced with a new one, it is necessary to reset the life
counter in the Service menu. For details of how to reset the counter, see
page 3-30.
8.
Perform the Density Calibration in the Quality menu. For information about the density
calibration, see
DENSITY CALIBRATION
Reassembly Procedures
1.
Align the spring with the post on the plastic housing.
2.
Make sure that the drive gear on the transfer roller is aligned with the coupling on the right
side of the printer.
3.
Make sure that the spring action of the transfer roller is working correctly.
Caution:
Ensure that the High-Voltage Bias Spring is making contact with the Transfer
Roller Bias Contact Plate [1].
Phaser® 6120 Color Laser Printer Service Manual
Maintenance Procedures
on page 3-18.
[1]
transrollspr
2-11
Service Menu
on