Typical connection mode 11 (C11)

Description:
1. Motor start/stop and rotation direction can be controlled via DI1 and DI2, motor speed via
The DIP-switch settings
DIP-switch (AO): Depends on external RPM Meter
DIP-switch (AI): The setting in this application is inactive
Table 6-11
Par. No.
r0007
P0610
P0701
P0702
P0703
P1000
* "xx" means current application macro.
SINAMICS V10
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
the operator panel.
3 AC 400 V
L1
L2
L3
PE
PE L1
L2
L3
SINAMICS V10 Inverter
U V
W
M
3~
Factory defaut setting:
Factory defaut setting:
Lit while inverter running or alarm
Dim while inverter fault
Inverter running: Lamp ON
Dim while inverter fault
Inverter in any other status: Lamp OFF
Figure 6-11
Typical connection mode 11 (C11)
Select connection macro C10 with the operator panel after the wiring (please refer to
"Operation mode
will be automatically finished.)
Parameter name
Selected connection macro and application macro
Motor I
t reaction
2
Function of digital input 1
Function of digital input 2
Function of digital input 3
Selection of frequency setpoint
Fuse
Contactor
8
5
6
7
DI1
DI2
+24V
0V
Digital Input
I
AO
(mA)
Digital Output
DO1 DO1
1
2
N
L
220 AC Supply
- Connection macro selection", and then below parameter settings
6.1 Typical connection modes
Connection macro: C11
RPM Meter
9
16
17
13
14
15
DI3
AI1- AI1+ AO1+
+10V
0V
Analog Input/Analog Output
I
U
U
AI
AO
AI
(V)
(V)
(mA)
DIP-switches
RS-485
Com A Com B
Operator Panel
Range
C0100 - C1105
0 - 2
0 - 99
0 - 99
0 - 99
0 - 53
Commissioning
N
18
AO1-
P6V5 M
Unit
Default
- -
C10xx*
- -
2
- -
1
- -
12
- -
9
- -
5
55