Commissioning
6.3 Operator panel overview
Legend
Meaning
STOP key
STOP
RUN key
运行
RUN
OK button
OK
The factory default control mode is "LOC". In most cases, "LOC" is used for debugging purpose only.
1)
For the description of OFF1 function, see "Notes on OFF functions" in Chapter 7.
2)
For the description of OFF2 function, see "Notes on OFF functions" in Chapter 7.
3)
6.3.2

Various data displays

Table 6-14
Various data displays
Display
Example
-8.8.8.8.8
- - - - -
busy
d xxx
C xx
A xx
60
Function
Press STOP < 2 s: Motor ramp-down (OFF1)
Press STOP > 2 s: Motor to coast to a standstill (OFF2)
Pressing RUN starts motor.
Press OK:
Turn OK clockwise:
Turn OK
counterclockwise:
Meaning
Inverter display is lighted
Inverter initializing
Inverter is confirming the selected
connection macro or application
macro, or inverter is busy
Actual DC-link voltage
Connection macro available for
selection
Application macro available for
selection
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
2)
1. Acknowledge fault
2. Loop through motor status data display
3. Confirm the selected connection macro or application
macro
4. Go from a parameter number into its value setting or
into its parameters index no. and back
1. Go into the next parameter no., connection macro or
application macro.
2. Accelerate the motor
3. Increase the setpoint
1. Go into the last parameter no., connection macro or
application macro.
2. Decelerate the motor
3. Decrease the setpoint
Remarks
-
-
-
-
There are 10 connection macros available for
selection: C01 ... C11.
There are 6 application macros available for
selection : A00 ... A05
3)
SINAMICS V10