Motor Data - Siemens SINAMICS V10 Operating Instructions Manual

Table of Contents

Advertisement

Commissioning
6.4 Quick commissioning
NOTICE
"P" of parameters in quick commissioning is followed by a ".", for example, P.0304 and P.
1080.
Motor parameters can only be set in "Operation mode ① - Quick motor data setting
(Page 66)", but in "Operation mode
except for P0305 are read-only.

Motor data

In SINCAMICS V10, the factory default motor parameter values are set based on SIEMENS
1LG0 4-pole AC motors. (See table below for default motor data settings of SIEMENS 1LG0
4-pole AC motors.) You can change the defaults against data shown on the rating plate of your
motor connected.
Rated inverter
Motor
output power (kW)
frame
size
0.55
80M
0.75
80M
1.1.
90S
1.50
90L
2.20
100L
3.00
100L
4.00
112M
5.50
132S
7.50
132M
11.00
160M
15.00
160L
18.50
180M
22.00
180L
64
SIEMENS 1LG0 4-pole AC motors
Motor Type
Rated speed
1LG0080-4AA..
1390
1LG0083-4AA..
1380
1LG0090-4AA..
1390
1LG0096-4AA..
1390
1LG0106-4AA..
1410
1LG0107-4AA..
1410
1LG0113-4AA..
1435
1LG0130-4AA..
1440
1LG0133-4AA..
1440
1LG0163-4AA..
1460
1LG0166-4AA..
1460
1LG0183-4AA..
1470
1LG0186-4AA..
1470
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
- Acess all the parameters", all the motor parameters
Rated motor
(rpm)
efficiency
(%)
71.0
73.0
76.2
78.5
81.0
82.8
84.5
86.0
87.2
89.0
90.0
90.6
91.4
Power
Rated
factor
current (A)
0.750
1.57
3.8
0.760
2.05
5.2
0.760
2.89
7.6
0.790
3.67
10.3
0.800
5.16
14.9
0.810
6.80
20.3
0.820
8.80
26.6
0.820
11.80
36.5
0.840
15.60
49.7
0.830
22.60
72.0
0.840
30.10
98.1
0.860
36.10
120.2
0.860
42.50
143.0
SINAMICS V10
Rated
torque
(Nm)