Typical Connection Mode 2 (C02) - Siemens SINAMICS V10 Operating Instructions Manual

Table of Contents

Advertisement

Commissioning
6.1 Typical connection modes
Par. No.
P1000
P0725
* "xx" means current application macro.

Typical connection mode 2 (C02)

Description:
1. In LOC mode, motor start/stop, rotation direction and speed can be controlled via the
2. In REM mode, motor start/stop can be controlled via an external signal source connected
The DIP-switch settings
DIP-switch (AO): Depends on external RPM Meter
DIP-switch (AI): The setting in this application is inactive
42
Parameter name
Selection of frequency setpoint
PNP/NPN digital inputs
operator panel.
to DI3, MOP-up (for increasing motor frequency)/MOP-down (for decreasing motor
frequency) via external signal sources connected to DI1 and DI2.
3 AC 400 V
L1
L2
L3
PE
Fuse
Contactor
L2
L3
PE L1
SINAMICS V10 Inverter
U V
W
M
3~
Factory defaut setting:
Lit while inverter running or alarm
Dim while inverter fault
Inverter running: Lamp ON
Inverter in any other status: Lamp OFF
Figure 6-2
Typical connection mode 2 (C02)
5
6
7
8
9
13
+24V
0V
DI1
DI2
DI3
+10V
Digital Input
I
I
U
U
AO
AI
AI
AO
(V)
(V)
(mA)
(mA)
DIP-switches
Digital Output
DO1 DO1
1
2
N
L
220 AC Supply
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
Range
Unit
0 - 53
- -
0 - 1
- -
Connection macro: C02
RPM Meter
N
16
18
14
15
17
AI1- AI1+ AO1+
AO1-
0V
Analog Input/Analog Output
RS-485
Com A Com B
P6V5 M
Operator Panel
Default
5
1
SINAMICS V10