5.1 Mechanical installation
Figure 5-2

Mounting clearance

You can mount inverters one next to another or one above another with the clearance below:
● Allow at least 100 mm clearance above and below the inverter..
● Allow at least specified clearance A (see Figure 5-3 and Table 5-1 below) between the
Table 5-1
Inverters positioned side by side
Frame Size A ↔ Frame Size A
Frame Size B ↔ Frame Size A / B
Frame Size C ↔ Frame Size A / B / C
Frame Size D ↔ Frame Size A / B / C / D
22

Allowed mounting angle between inverter and the horizon

inverters.
≥100 mm
A
SINAMICS V10
SINAMICS V10
≥100 mm
Figure 5-3

Inverter mounting clearance

Requirements for inverter mounting clearance

≥100 mm
A
SINAMICS V10
SINAMICS V10
≥100 mm
Minimum clearance ("A") in mm
50
50
70
75
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)