Parameters Available For Setting In This Mode; Operation Mode ④ - Common Application Macro Specific Parameter Setting - Siemens SINAMICS V10 Operating Instructions Manual

Table of Contents

Advertisement

Commissioning
6.6 Overview of various operation modes
6.6.4
Operation mode ④ - Common application macro specific parameter setting
Common application macro specific parameter setting
Figure 6-24
Common application macro specific parameter setting

Parameters available for setting in this mode

P1080, P1082, P1120, P1121, P1210 and P1310
NOTICE
Parameters available for setting in this mode can also be shown in the "Access all the
parameters" mode. To easily differentiate, the parameter number shown in the "Common
application macro specific parameter setting" mode has a dot (.) after "P".
You can set a parameter value either in this mode or in the "Access all parameters" mode.
Once the value is set, it will be simultaneously updated in both modes.
Parameter setting in "Application macro specific parameter setting" mode
See the second figure in topic "Operation mode ① - Quick motor data setting (Page 66)" for
parameterization method.
Button/keys inactive in this mode
The STOP, RUN and LOC/REM keys are inactive in this mode.
70
Turn
Turn
OK
Turn
OK
OK
Operating Instructions, 08/2011, A5E03453178 (this is not an order number)
. . .
Turn
OK
SINAMICS V10

Hide quick links:

Advertisement

Table of Contents
loading