Menu 21: Second Motor Parameters - Emerson unidrive m200 User Manual

Hide thumbs Also See for unidrive m200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
10.17

Menu 21: Second motor parameters

Parameter
21.001
M2 Maximum Reference Clamp
21.002
M2 Minimum Reference Clamp
21.003
M2 Reference Selector
21.004
M2 Acceleration Rate 1
21.005
M2 Deceleration Rate 1
21.006
M2 Motor Rated Frequency
21.007
M2 Motor Rated Current
21.008
M2 Motor Rated Speed
21.009
M2 Motor Rated Voltage
21.010
M2 Motor Rated Power Factor
21.011
M2 Number of Motor Poles*
21.012
M2 Stator Resistance
21.014
M2 Transient Inductance
21.015
Motor 2 Active
21.016
M2 Motor Thermal Time Constant 1
M2 Frequency Controller Proportional
21.017
Gain Kp1
M2 Frequency Controller Integral
21.018
Gain Ki1
M2 Frequency Controller Differential
21.019
Feedback Gain Kd1
21.022
M2 Current Controller Kp Gain
21.023
M2 Current Controller Ki Gain
21.024
M2 Stator Inductance
21.025
M2 Saturation Breakpoint 1
21.026
M2 Saturation Breakpoint 3
21.027
M2 Motoring Current Limit
21.028
M2 Regenerating Current Limit
21.029
M2 Symmetrical Current Limit
21.033
M2 Low Frequency Thermal Protection Mode
21.041
M2 Saturation Breakpoint 2
21.042
M2 Saturation Breakpoint 4
* When read via serial communications, this parameter will show pole pairs.
RW Read / Write
RO
Read only
ND
No default value
NC
Not copied
156
Electrical
Getting
Basic
Running the
installation
started
parameters
Range ( Ú )
OL
±VM_POSITIVE_REF_CLAMP Hz
±VM_NEGATIVE_REF_CLAMP2
A1.A2 (0), A1.Pr (1), A2.Pr (2), PrESEt (3), PAd
(4), rES (5), PAd.rEF (6)
±VM_ACCEL_RATE
±VM_ACCEL_RATE
0.00 to VM_SPEED_FREQ_REF_UNIPOLAR Hz
±VM_RATED_CURRENT A
0.0 to 80000.0 rpm
±VM_AC_VOLTAGE_SET V
0.00 to 1.00
Auto (0) to 32 (16)
0.0000 to 99.9999
0.000 to 500.000 mH
Off (0) or On (1)
1 to 3000 s
0.00 to 4000.00
0.000 to 600.000
0.00 to 5000.00 mH
±VM_MOTOR2_CURRENT_LIMIT %
±VM_MOTOR2_CURRENT_LIMIT %
±VM_MOTOR2_CURRENT_LIMIT %
0 to 1
Num Number parameter
PT
Protected parameter
NV Media
Optimization
motor
Card
Default ( Ö )
RFC-A
OL
50Hz: 50.00 Hz
60Hz: 60.00 Hz
50Hz: 50.00 Hz
60Hz: 60.00 Hz
Maximum Heavy Duty Rating (11.032)
50 Hz: 1500.0 rpm
60 Hz: 1800.0 rpm
110 V drive: 230 V
200 V drive: 230 V
400 V drive 50Hz: 400 V
400 V drive 60Hz: 460 V
575 V drive: 575 V
690 V drive: 690 V
179 s
0.000 to 200.000 s/rad
0.00 to 655.35 s²/rad
0.00000 to
0.65535 1/rad
0.0 to 100.0 %
0.0 to 100.0 %
165.0 %
165.0 %
165.0 %
0.0 to 100.0 %
0.0 to 100.0 %
Bit
Bit parameter
Txt
Text string
RA
Rating dependent
US
User save
Advanced
Technical data
Diagnostics
parameters
RFC-A
RW
Num
0.00
RW
Num
A1.A2 (0)
RW
Txt
5.0
RW
Num
10.0
RW
Num
RW
Num
RW
Num
50 Hz: 1450.0rpm
RW
Num
60 Hz 1750.0 rpm
RW
Num
0.85
RW
Num
Auto (0)
RW
Num
0.0000
RW
Num
0.000 mH
RW
Num
RO
Bit
179 s
RW
Num
0.100 s/rad
RW
Num
0.10 s²/rad
RW
Num
0.00000 1/rad
RW
Num
20.00
RW
Num
40.000
RW
Num
0.00 mH
RW
Num
50.0 %
RW
Num
75.0 %
RW
Num
175.0 %
RW
Num
175.0 %
RW
Num
175.0 %
RW
Num
0
RW
Num
0.0 %
RW
Num
0.0 %
RW
Num
Bin
Binary parameter
PS
Power-down save
Unidrive M200 / M201 User Guide
Issue Number: 4
UL Listing
Type
US
US
US
US
US
RA
US
RA
US
US
RA
US
RA
US
US
RA
US
RA
US
ND
NC
PT
US
US
US
US
US
US
RA
US
US
US
RA
US
RA
US
RA
US
US
US
US
FI
Filtered
DE
Destination

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents