Epsilon Ei DeviceNet Drive Reference Manual
This section lists all parameters available for Epsilon Ei DeviceNet drive. The tables provide the
following information about each parameter:
Name
The parameter's name
DeviceNet Data Type
INT, UINT = 16 bit value
DINT, UDINT = 32 bit value
BOOL = Bit
Word = Bitmap 16
DWord = Bitmap 32
String: XXX = ASCII characters of XXX length, padded with white space
Class, Instance, Attribute
The path necessary to access the parameter.
By Name
*Note 1*
The instance number will be one more than the number of the index, jog, input or output. For
example, Index0 will have an instance of 1 (0x01) and Index 14 will have an instance of 15
(0x0F). If the parameter is unnumbered, the instance will be one.
Name
AnalogOutput.AnalogOutputInstance#.Channel
AnalogOutput.AnalogOutputInstance#.Offset
AnalogOutput.AnalogOutputInstance#.Scale
AnalogOutput.AnalogOutputInstance#.Select
DeviceNet.DeviceNetIdentityObject.DeviceStatus
DeviceNet.DeviceNetIdentityObject.DeviceType
DeviceNet.DeviceNetIdentityObject.HeartbeatInterval
DeviceNet.DeviceNetIdentityObject.VendorID
Execute.ExecuteClearFault
Execute.ExecuteReadBaseDriveNVMtoRAM
DN Data Type
DINT
DINT
UINT
UINT
DINT
UINT
BOOL
BOOL
Get other manuals https://www.bkmanuals.com
Drive Parameters
Class
Instance
INT
100 (0x64)
See Note 1
100 (0x64)
See Note 1
100 (0x64)
See Note 1
INT
100 (0x64)
See Note 1
1 (0x01)
1 (0x01)
1 (0x01)
1 (0x01)
1 (0x01)
1 (0x01)
1 (0x01)
1 (0x01)
101 (0x65)
1 (0x01)
101 (0x65)
1 (0x01)
Attribute
1 (0x01)
2 (0x02)
3 (0x03)
4 (0x04)
5 (0x05)
2 (0x02)
10 (0x0A)
1 (0x01)
1 (0x01)
2 (0x02)
61