Safety
Product
Mechanical
information
information
installation
7
Analog output 1
Default function
Frequency output
Type of output
Unipolar single-ended analog voltage
Voltage range
+10 V
Maximum offset
15 mV
• 2 k
Load resistance
Protection
Short circuit relative to 0 V
Resolution
0.1 %
Sample / update period
5 ms
9
+24 V user output
Default function
Supply for external digital devices
Voltage tolerance
±20 %
Maximum output current
100 mA
Protection
Current limit and trip
10
Digital I/O 1
Default function
Type
Input / output mode controlled by ...
Operating as in input
Absolute maximum applied voltage
range
Impedance
Input threshold
Operating as an output
Nominal maximum output current
Maximum output current
Common to all modes
Voltage range
Sample / update period
11
Digital Input 2
12
Digital Input 3
13
Digital Input 4
Terminal 11 default function
Terminal 12 default function
Terminal 13 default function
Type
Voltage range
Absolute maximum applied voltage
range
Impedance
Input threshold
Sample / update period
Unidrive M200 / M201 User Guide
Issue Number: 4
Electrical
Getting
Basic
Running the
installation
started
parameters
AT ZERO FREQUENCY output
Positive logic digital input, positive logic
voltage source output.
PWM or frequency output modes can be
selected.
Pr 08.031
-8 V to +30 V relative to 0 V
6.8 k
10 V ±0.8 V from IEC 61131-2
50 mA
100 mA (total including +24 Vout)
0 V to +24 V
2 ms when routed to destinations
Pr 06.035 or Pr 06.036, otherwise 6 ms
DRIVE ENABLE input
RUN FORWARD input
RUN REVERSE input
Positive logic only digital inputs
0 V to +24 V
-18 V to +30 V relative to 0 V
6.8 k
10 V ±0.8 V from IEC 61131-2
2 ms when routed to destinations
Pr 06.035 or Pr 06.036, otherwise 6 ms.
NV Media
Optimization
motor
Card
14
Digital Input 5
Terminal 14 default function
Type
Voltage range
Absolute maximum applied
voltage range
Impedance
Input threshold
Sample / update period
41
Relay contacts
42
Default function
Contact voltage rating
Contact maximum current rating
Contact minimum recommended
rating
Contact type
Default contact condition
Update period
To prevent the risk of a fire hazard in the event of a fault, a
fuse or other over-current protection must be installed in the
relay circuit.
WARNING
Advanced
Technical data
Diagnostics
parameters
Analog INPUT 1 / INPUT 2 select
Positive logic only digital input. Frequency
input or motor thermistor input (bias for
DIN44081 ptc, KTY84, PT1000, PT2000
and other types) mode can be selected.
0 V to +24 V
-18 V to +30 V relative to 0 V
6.8 k
10 V ±0.8 V from IEC 61131-2
2 ms when routed to destinations Pr 06.035
or Pr 06.036, otherwise 6 ms.
Drive OK indicator
240 Vac, Installation over-voltage category II
2 A AC 240 V
4 A DC 30 V resistive load
0.5 A DC 30 V inductive load (L/R = 40 ms)
12 V 100 mA
Normally open
Closed when power applied and drive OK
4 ms
UL Listing