Menu 11: General Drive Set-Up - Emerson unidrive m200 User Manual

Hide thumbs Also See for unidrive m200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
10.11

Menu 11: General drive set-up

Parameter
11.018
Status Mode Parameter 1
11.019
Status Mode Parameter 2
11.020
Reset Serial Communications
11.021
Customer Defined Scaling
11.022
Parameter Displayed At Power-up
11.023
Serial Address
11.024
Serial Mode
11.025
Serial Baud Rate
11.026
Minimum Comms Transmit Delay
11.027
Silent Period
11.028
Drive Derivative
11.029
Software Version
11.030
User Security Code
11.031
User Drive Mode
11.032
Maximum Heavy Duty Rating
11.033
Drive Rated Voltage
11.034
Drive Configuration
11.035
Power Software Version
11.036
NV Media Card File Previously Loaded
11.037
NV Media Card File Number
11.038
NV Media Card File Type
11.039
NV Media Card File Version
11.042
Parameter Cloning
11.043
Load Defaults
11.044
User Security Status
11.045
Select Motor 2 Parameters
11.046
Defaults Previously Loaded
11.052
Serial Number LS
11.053
Serial Number MS
11.054
Drive Date Code
11.060
Maximum Rated Current
11.061
Full Scale Current Kc
11.063
Product Type
11.064
Product Identifier Characters
11.065
Frame size and voltage code
11.066
Power Stage Identifier
11.067
Control Board Identifier
11.068
Drive current rating
11.070
Core Parameter Database Version
11.072
NV Media Card Create Special File
11.073
NV Media Card Type
11.075
NV Media Card Read-only Flag
11.076
NV Media Card Warning Suppression Flag
11.077
NV Media Card File Required Version
11.079
Drive Name Characters 1-4
11.080
Drive Name Characters 5-8
11.081
Drive Name Characters 9-12
11.082
Drive Name Characters 13-16
11.084
Drive Mode
11.085
Security Status
11.086
Menu Access Status
11.091
Additional Identifier Characters 1
11.092
Additional Identifier Characters 2
11.093
Additional Identifier Characters 3
11.094
Disable String Mode
11.097
AI ID Code
RW
Read / Write
RO
Read only
ND
No default value
NC
Not copied
IP
IP address
Mac
Mac address
144
Electrical
Getting
Basic
Running the
installation
started
parameters
Range ( Ú )
OL
0.000 to 30.999
0.000 to 30.999
Off (0) or On (1)
0.000 to 10.000
0.000 to 0.080
8.2NP (0), 8.1NP (1), 8.1EP (2),
8.1OP (3), 8.2NP E (4), 8.1NP E (5),
8.1EP E (6), 8.1OP E (7), 7.1EP (8),
7.1OP (9), 7.1EP E (10), 7.1OP E (11)
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
9600 (5), 19200 (6), 38400 (7), 57600 (8),
76800 (9), 115200 (10)
0 to 250 ms
0 to 250 ms
00.00.00 to 99.99.99
OPEn.LP (1), rFC-A (2)
0.00 to 9999.99 A
110V (0), 200V (1), 400V (2),
575V (3), 690V (4)
AV (0), AI (1), AV.Pr (2), AI.Pr (3),
PrESEt (4), PAd (5), PAd.rEF (6), E.Pot (7),
torque (8), Pid (9)
00.00.00 to 99.99.99
NonE (0), OPEn.LP (1), rFC-A (2)
NonE (0), rEAd (1), Prog (2),
Auto (3), boot (4)
NonE (0), Std (1), US (2)
LEVEL.0 (0), ALL (1), r.onLy.0 (2), r.onLy.A (3),
StAtUS (4), no.Acc (5)
0 to 999999
0 to 999999
0.000 to 999.999 A
0.000 to 999.999 A
200 (1295134768) to (2147483647)
0.00 to 99.99
NonE (0), rES (1), Sd.CArd (2)
Off (0) or On (1)
Off (0) or On (1)
(-2147483648) to
(-2147483648) to
(-2147483648) to
(-2147483648) to
OPEn.LP (1), rFC-A (2)
NonE (0), r.onLy.A (1), StAtUS (2), no.Acc (3)
LEVEL.0 (0), ALL (1)
(-2147483648) to (2147483647)
(-2147483648) to (2147483647)
(-2147483648) to (2147483647)
Off (0) or On (1)
NonE (0), Sd.CArd (1), rS-485 (2),
boot (3), rS-485 (4)
Num
Number parameter
Bit
PT
Protected parameter
RA
Date
Date parameter
Time
NV Media
Optimization
motor
Card
Default ( Ö )
RFC-A
OL
1 to 247
0 to 255
0 to 9999
0 to 999
0 to 999
0 to 9999
1 (0), 2 (1)
0 to 2000
0 to 9999
0 to 255
0 to 999
0 to 255
0 to 255
0 to 32767
0 to 1
0 to 9999
(-2147483647)
- - - - (757935405)
(-2147483647)
- - - - (757935405)
(-2147483647)
- - - - (757935405)
(-2147483647)
- - - - (757935405)
Bit parameter
Txt
Text string
Rating dependent
US
User save
Time parameter
SMP
Slot,menu,parameter
Advanced
Technical data
Diagnostics
parameters
Type
RFC-A
2.001
RW
Num
4.020
RW
Num
RW
Bit
ND
1.000
RW
Num
0.010
RW
Num
1
RW
Num
8.2NP (0)
RW
Txt
19200 (6)
RW
Txt
2 ms
RW
Num
0 ms
RW
Num
RO
Num
ND
RO
Ver
ND
RW
Num
ND
RW
Txt
ND
RO
Num
ND
RO
Txt
ND
AV (0)
RW
Txt
RO
Ver
ND
0
RO
Num
0
RW
Num
RO
Txt
ND
RO
Num
ND
NonE (0)
RW
Txt
NonE (0)
RW
Txt
LEVEL.0 (0)
RW
Txt
ND
1 (0)
RW
Txt
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Chr
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
0
RW
Num
RO
Num
ND
RO
Bit
ND
RO
Bit
ND
RW
Num
ND
RW
Chr
RW
Chr
RW
Chr
RW
Chr
RO
Txt
ND
RO
Txt
ND
RO
Txt
ND
RO
Chr
ND
RO
Chr
ND
RO
Chr
ND
Off (0)
RW
Bit
RO
Txt
ND
Bin
Binary parameter
PS
Power-down save
Chr
Character parameter
Unidrive M200 / M201 User Guide
UL Listing
PT
US
PT
US
NC
US
PT
US
US
US
US
US
US
NC
PT
NC
PT
NC
PT
US
NC
PT
US
NC
PT
NC
PT
PT
US
NC
PT
NC
PT
NC
PT
NC
PT
NC
US
NC
PT
US
NC
PT
US
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
NC
PT
NC
PT
NC
PT
NC
PT
PT
US
PT
US
PT
US
PT
US
NC
PT
NC
PT
PS
NC
PT
PS
NC
PT
NC
PT
NC
PT
PT
US
NC
PT
FI
Filtered
DE
Destination
Ver
Version number
Issue Number: 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents