Emerson unidrive m200 User Manual page 128

Hide thumbs Also See for unidrive m200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
05.001
Output Frequency
05.002
Output Voltage
05.003
Output Power
05.004
Motor Rpm
05.005
D.C. Bus Voltage
05.006
Motor Rated Frequency
05.007
Motor Rated Current
05.008
Motor Rated Speed
05.009
Motor Rated Voltage
05.010
Motor Rated Power Factor
05.011
Number Of Motor Poles*
05.012
Autotune
05.013
Dynamic V To F Select / Flux Optimization Select
05.014
Control Mode
05.015
Low Frequency Voltage Boost
05.017
Stator Resistance
05.018
Maximum Switching Frequency
05.019
High Stability Space Vector Modulation
05.020
Over Modulation Enable
05.024
Transient Inductance
05.025
Stator Inductance
05.026
High Dynamic Performance Enable
05.027
Enable Slip Compensation
05.028
Flux Control Compensation Disable
05.029
Saturation Breakpoint 1
05.030
Saturation Breakpoint 3
05.031
Voltage Controller Gain
05.032
Torque Per Amp
05.033
Slip Compensation Limit
05.034
Percentage Flux
05.035
Auto-switching Frequency Change Disable
05.036
Slip Compensation Filter
05.037
Switching Frequency
05.040
Spin Start Boost
05.042
Reverse Output Phase Sequence
05.059
Maximum Deadtime Compensation
05.060
Current At Maximum Deadtime Compensation
05.061
Disable Deadtime Compensation
05.062
Saturation Breakpoint 2
05.063
Saturation Breakpoint 4
05.074
Boost End Voltage
05.075
Boost End Frequency
05.076
Second Point Voltage
05.077
Second Point Frequency
05.078
Third point voltage
05.079
Third point frequency
05.080
Low acoustic noise enable
Change to maximum drive switching frequency
05.081
at low output current
05.082
Motor Rated Power
05.083
Voltage Shelving Disable
05.084
Low Frequency Slip Boost
* If this parameter is read via serial communications, it will show pole pairs.
RW Read / Write
RO
Read only
ND
No default value
NC
Not copied
128
Electrical
Getting
Basic
Running the
installation
started
parameters
Range ( Ú )
OL
±VM_SPEED_FREQ_REF Hz
±VM_AC_VOLTAGE V
±VM_POWER kW
±80000 rpm
±VM_DC_VOLTAGE V
0.00 to VM_SPEED_FREQ_REF_UNIPOLAR Hz
±VM_RATED_CURRENT A
0.0 to 80000.0 rpm
±VM_AC_VOLTAGE_SET V
0.00 to 1.00
Auto (0) to 32 (16)
0 to 2
0 to 1
Ur.S (0), Ur (1),
Fd (2), Ur.Auto (3),
Ur.I (4), SrE (5)
0.0 to 50.0 %
0.0000 to 99.9999
0.667 (0), 1 (1), 2 (2),
3 (3), 4 (4), 6 (5), 8 (6),
12 (7), 16 (8) kHz
Off (0) or On (1)
Off (0) or On (1)
0.000 to 500.000 mH
0.00 to 5000.00 mH
±150.0 %
Off (0) or On (1)
1 to 30
0.00 to 500.00 Nm/A
0.00 to 10.00 Hz
0 to 2
64 (0), 128 (1), 256 (2),
512 (3) ms
0.667 (0), 1 (1), 2 (2),
3 (3), 4 (4), 6 (5), 8 (6),
12 (7), 16 (8) kHz
0.0 to 10.0
Off (0) or On (1)
0.000 to 10.000 µs
0.00 to 100.00 %
Off (0) or On (1)
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
Off (0) or On (1)
Off (0) or On (1)
±VM_POWER kW
Off (0) or On (1)
0.0 to 100.0 %
Num Number parameter
PT
Protected parameter
NV Media
Optimization
motor
Card
RFC-A
OL
50 Hz: 50.00 Hz, 60 Hz: 60.00 Hz
Maximum Heavy Duty Rating (11.032)
50 Hz: 1500.0 rpm
60 Hz: 1800.0 rpm
110 V drive: 230 V, 200 V drive: 230 V
400 V drive 50Hz: 400 V
400 V drive 60Hz: 460 V
575 V drive: 575 V
690 V drive: 690 V
0 to 3
Ur.I (4)
2 (2), 3 (3), 4 (4), 6 (5),
8 (6), 12 (7), 16 (8) kHz
Off (0)
Off (0)
Off (0) or On (1)
100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
5.00 Hz
0.0 to 150.0 %
128 (1) ms
2 (2), 3 (3), 4 (4), 6 (5),
8 (6), 12 (7), 16 (8) kHz
0.0 to 100.0 %
0.0 to 100.0 %
50.0 %
50.0 %
55.0 %
55.0 %
75.0 %
75.0 %
Off (0)
Off (0)
0.0 %
Bit
Bit parameter
Txt
Text string
RA
Rating dependent
US
User save
Advanced
Technical data
Diagnostics
parameters
Default ( Ö )
RFC-A
RO
Num ND NC PT
RO
Num ND NC PT
RO
Num ND NC PT
RO
Num ND NC PT
RO
Num ND NC PT
RW
Num
RW
Num
50 Hz: 1450.0 rpm
RW
Num
60 Hz: 1750.0 rpm
RW
Num
0.85
RW
Num
Auto (0)
RW
Num
0
RW
Num
0
RW
Num
RW
Txt
3.0 %
RW
Num
0.0000
RW
Num
3 (3) kHz
RW
Txt
RW
Bit
RW
Bit
0.000 mH
RW
Num
0.00 mH
RW
Num
Off (0)
RW
Bit
RW
Num
Off (0)
RW
Bit
50.0 %
RW
Num
75.0 %
RW
Num
1
RW
Num
RO
Num ND NC PT
RW
Num
RO
Num ND NC PT
0
RW
Num
RW
Txt
RO
Txt
1.0
RW
Num
Off (0)
RW
Bit
0.000 µs
RO
Num
0.00 %
RO
Num
Off (0)
RW
Bit
0.0 %
RW
Num
0.0 %
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Bit
Off (0)
RW
Bit
0.00 kW
RW
Num
RW
Bit
RW
Num
Bin
Binary parameter
PS
Power-down save
Unidrive M200 / M201 User Guide
Issue Number: 4
UL Listing
Type
FI
FI
FI
FI
FI
RA
US
RA
US
US
RA
US
RA
US
US
NC
US
US
US
RA
US
RA
US
US
US
RA
US
RA
US
US
US
US
US
US
US
US
US
US
ND NC PT
US
US
NC PT
US
NC PT
US
US
US
US
US
US
US
US
US
US
US
US
RA
US
US
FI
Filtered
DE
Destination

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents