Menu 11: General Drive Set-Up - Emerson MP25A4 User Manual

Mentor mp series high performance dc drive 25a to 7400a, 480v to 690v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
Installation
11.11

Menu 11: General drive set-up

Parameter
11.21 Parameter scaling
11.22 Parameter displayed at power-up
11.23 Serial address
11.24 Serial mode
11.25 Baud rate
11.26 Minimum comms transmit delay
11.29 Software version
11.30 User security code
11.32 Current rating
11.33 Drive voltage rating
11.34 Software sub-version
11.35 Number of modules
SMARTCARD parameter data previously
11.36
loaded
11.37 SMARTCARD data number
SMARTCARD data type/
11.38
mode
11.39 SMARTCARDdata version
11.40 SMARTCARD data checksum
11.41 Status mode timeout
11.42 Parameter copying
11.44 Security status
11.45 Select motor 2 parameters
11.46 Defaults previously loaded
Drive Onboard Application Lite Ladder
11.47
Program Enable
Drive Onboard Application Lite Ladder
11.48
Program Status
Drive Onboard Application Lite Ladder
11.49
Program Events
Drive Onboard Application Lite Ladder
11.50
Program Maximum Scan Time
Drive Onboard Application Lite Ladder
11.51
Program First Run
11.52 Drive serial number
11.53 Build location
11.55 Drive rating number
11.56 Power PCB software version
11.57 Serial programmable source
11.58 Serial scaling
Mentor II Parameter Emulator Module
11.59
Control
11.60 Application parameters
11.61 Application parameters
11.62 Full power discharge time
11.63 Full power discharge period
11.64 External discharge resistance
11.65 External resistor temperature
11.66 Suppressor voltage
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
* Modes 1 and 2 are not US (i.e. not saved when drive parameters are saved), mode 3 and 4 are US. Therefore this parameter can only be saved to
EEPROM if it has a value of 0, 3 or 4.
124
Electrical
Getting
Basic
Running the
installation
started
parameters
Range( )
0 to 9.999
0 to 00.90
{Si02, 0.67}
{Si01, 0.66}
0 to 250ms
{di14, 0.49}
1.0 to 99.99
0 to 10000.0A
0 (480), 1 (575), 2 (690)
0 to 1003
0 to 9999
0 to 65335
0 to 250s
{SE09, 0.30}
{SE14, 0.35}
OFF (0) or On (1)
-128 to +127
0 to 65535
0 to 65335ms
OFF (0) or On (1)
0 to 999 999 999
1.00 to 99.99
Pr 0.00 to 22.99
0 to 1999
16000 to -16000
0 to 25.0s
0 to 1500.0s
0 to 9999Ω
0 to 100%
0 to 2000V
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
SMARTCARD
Optimization
motor
operation
0 to 247
0 to 2
0 to 9
0 to 999
0 to 99
0 to 4
0 to 999
0 to 18
0 to 4
0 to 2
0 to 2
0 to 2
0 to 255
0 to 56
0 to 3
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
Default( )
1.000
RW Uni
00.40
RW Uni
1
RW Uni
1
RW Txt
6
RW Txt
2
RW Uni
RO Uni
0
RW Uni
RO Uni
RO Txt
RO Uni
RW Uni
RO Uni
0
RW Uni
RO Uni
0
RW Uni
RO Uni
240
RW Uni
0
RW Txt
0
RW Txt
OFF (0)
RW Bit
Eur: or USA: 0
RO Txt
2
RW Uni
RO
Bi
RO Uni
RO Uni
RO Bit
RO Uni
RO Uni
RO Uni
RO Uni
Pr 0.00
RW Uni
1000
RW Uni
0
RW Uni
RW Uni
RW Uni
RW Uni
0.0
RW Uni
0
RW Uni
RO
RO
Txt
Text string
US
User save
PS
Mentor MP User Guide
UL
information
Type
US
PT US
US
US
US
US
NC PT
NC PT PS
NC PT
NC PT
NC PT
PT US
NC PT US
NC
NC PT
NC
NC PT
US
NC
*
PT US
US
PT US
US
NC PT
NC PT PS
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
PT US
US
US
NC
NC
US
US
US
NC PT
NC PT
Power down save
Issue: 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents