Table 3-5: Sense Codes (Continued)
Sub
Error contents
code
84
More LUs than supportable ones
were specified for LUNs of the S-
VOL.
84
The P-VOL is in the status other
than normal or regressive.
84
The S-VOL is in the status other
than normal or regressive.
84
The primary sequence number is
different from the own Array ID.
84
The secondary sequence number
is different from the own Array ID.
84
The primary port number is not
supported.
84
The secondary port number is not
supported.
84
The P-VOL is a volume of
ShadowImage and in the status
other than SMPL.
84
The S-VOL is a volume of
ShadowImage and in the status
other than SMPL.
84
The P-VOL is a Sub LU of a unified
LU.
84
The S-VOL is a Sub LU of a unified
LU.
84
The P-VOL is a Cache Residency
LU.
84
The S-VOL is a Cache Residency
LU.
84
The P-VOL is reserved as a Cache
Residency LU.
84
The S-VOL is reserved as a Cache
Residency LU.
84
The P-VOL is a command device.
84
The S-VOL is a command device.
84
The LUNs of the P-VOL and S-VOL
are the same.
84
The P-VOL is a volume of
ShadowImage and in the pair
status other than PSUS or PSUE.
84
The S-VOL is a volume of
ShadowImage and in the pair
status other than PSUS or PSUE.
84
The LU to be paired with the P-VOL
is not an 
S-VOL.
84
The LUN of the P-VOL is higher
than 512 (1,023).
Maintenance log and tracing functions
Recommended Action
Make sure of the number of
the specified paired LU.
Check the status of the LU.
Check the status of the LU.
Check the Array ID.
Check the Array ID.
Check the specified port
number.
Check the specified port
number.
Check the pair status of the
LU.
Check the pair status of the
LU.
Check the status of the LU.
Check the status of the LU.
Check the status of the LU.
Check the status of the LU.
Check the status of the LU.
Check the status of the LU.
Check the status of the LU.
Check the status of the LU.
Check the specified LU.
Check the pair status.
Check the pair status.
Check the specified LU.
Make sure of the number of
the specified paired LU.