Hitachi AMS 2000 Reference Manual page 221

Adaptable modular storage/family command control interface (cci)
Hide thumbs Also See for AMS 2000:
Table of Contents

Advertisement

Sense
Detailed
code
code
9629
0026
9629
0027
9629
0028
9629
0029
9629
002C
9629
002D
9629
002E
9629
002F
9629
0030
9629
0031
9629
0032
9629
0033
9629
0034
9629
0035
9629
0036
9629
0037
9629
0038
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
Table 3-5: Sense Codes (Continued)
Sub
Error contents
code
84
The RAID group of the specified P-
VOL and 
S-VOL are the same.
84
The specified P-VOL is the
reserved LU.
84
The specified S-VOL is the
reserved LU.
84
The access level of the specified S-
VOL is other than the ordinary
one.
84
The specified MU number is 8 or
higher.
84
The specified primary port number
is beyond the limits of support.
84
The specified secondary port
number is beyond the limits of
support.
84
The specified primary sequence
number is different from the own
serial number.
84
The specified secondary sequence
number is different from the own
serial number.
84
The pair concerned is the one that
the instruction to start the
migration was issued by Navigator
2 or HiCommand.
84
The disk drives that configure a
RAID group, to which the specified
P-VOL belongs have been spun
down.
84
The disk drives that configure a
RAID group, to which the specified
S-VOL belongs have been spun
down.
84
The data migration status is "data
is being copied", "data copy fails",
or "data copy is completed".
84
The data migration status is
"access path is being switched" or
"access path switching fails".
84
The RAID group to which the
specified LU belongs indicates a
status other than Normal.
84
The LU created in DP pool was
specified as P-VOL or S-VOL.
84
The specified P-VOL and S-VOL are
LUs in the same DP pool.
Maintenance log and tracing functions
Recommended Action
Specify a different RAID
group.
Check the status of the LU.
Check the status of the LU.
Check the access revel of the
LU.
Make sure of the specified MU
number.
Check the specified primary
port number.
Check the specified
secondary port number.
Check the specified primary
sequence number.
Check the specified
secondary sequence number.
Check the owner ID of the
specified pair.
Check the status of the RAID
group.
Check the status of the RAID
group.
Check the data migration
status.
Check the data migration
status.
Retry after the status
becomes Normal.
Specify an LU other than the
LU created in DP pool.
Check the specified LUs.
3–65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents