Hitachi G800 Hardware Reference Manual

Hitachi G800 Hardware Reference Manual

Virtual storage platform
Hide thumbs Also See for G800:
Table of Contents

Advertisement

Hitachi Virtual Storage Platform G800
83-05-2x
Hardware Reference Guide
This document provides information about the system hardware components, mechanical, and
environmental specifications for the Hitachi Virtual Storage Platform G800 storage system.
MK-94HM8026-11
April 2018

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi G800

  • Page 1 Hitachi Virtual Storage Platform G800 83-05-2x Hardware Reference Guide This document provides information about the system hardware components, mechanical, and environmental specifications for the Hitachi Virtual Storage Platform G800 storage system. MK-94HM8026-11 April 2018...
  • Page 2 Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    Changes in this revision..................8 Document conventions..................8 Conventions for storage capacity values............10 Accessing product documentation..............11 Getting help......................11 Comments......................11 Chapter 1: Hitachi Virtual Storage Platform G800 hardware overview....................12 Block configuration.....................12 Unified configuration..................13 VSP G800 model....................13 Features......................16 Scalability......................16 Examples of supported VSP G800 configurations........
  • Page 4 Dense intermix drive tray with front panel bezel...........46 Dense intermix drive tray display LEDs............47 Dense intermix drive tray rear panel.............48 Chapter 4: Host port expansion chassis..........50 Host port expansion chassis front panel bezel LEDs........50 PCIe switchboard....................50 Contents Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 5 Chapter 7: Maintaining the storage system........61 Storing the storage system................61 Powering off the storage system................61 Removing cables....................62 Appendix A: Mechanical specifications for VSP G800 ....63 VSP G800 mechanical specifications..............63 Appendix B: Electrical specifications for VSP G800......73 Electrical specifications..................73 Appendix C: Environmental specifications for VSP G800....
  • Page 6 Hitachi Universal V2 Rack rail kits..............112 Hitachi Universal V2 Rack accessories............113 Third-party rack support for DB60 dense intermix drive trays......113 Appendix I: Power distribution units for Hitachi Universal V2 Rack .....................115 Americas single-phase PDU 1P30A-8C13-3C19UL.P........115 Americas single-phase PDU 1P30A-15C13-3C19UL.P........116 Americas three-phase PDU 3P30A-8C13-3C19UL.P........
  • Page 7 Appendix J: Regulatory compliance..........125 Appendix K: Safety and environmental notices.......127 Index....................129 Contents Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 8: Preface

    Preface This guide describes the hardware features and specifications of the VSP G800. Intended audience This document is intended for customers inquiring about the features and specifications of the storage system. Readers of this document should be familiar with the following: Data processing and RAID storage systems and their basic functions.
  • Page 9 { a | b } indicates that you must choose either a or b. This document uses the following icons to draw attention to information: Icon Label Description Note Calls attention to important or additional information. Preface Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 10: Conventions For Storage Capacity Values

    Logical capacity unit Value 1 block 512 bytes 1 cylinder Mainframe: 870 KB Open-systems: OPEN-V: 960 KB ■ Others: 720 KB ■ 1 KB 1,024 (2 ) bytes Preface Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 11: Accessing Product Documentation

    Getting help Hitachi Vantara Support Connect is the destination for technical support of products and solutions sold by Hitachi Vantara. To contact technical support, log on to Hitachi Vantara Support Connect for contact information: https://support.hitachivantara.com/en_us/ contact-us.html. Hitachi Vantara Community is a global online community for Hitachi Vantara customers, partners, independent software vendors, employees, and prospects.
  • Page 12: Chapter 1: Hitachi Virtual Storage Platform G800 Hardware Overview

    Chapter 1: Hitachi Virtual Storage Platform G800 hardware overview The Hitachi Virtual Storage Platform G800 is a modular, rack-mountable storage system, with various fixed storage capacity configurations of FMD DC2 flash storage devices. To deliver consistent low latency host response times and highest IOP performance across all host connection ports, hard-disk drives are supported in an all-flash configuration.
  • Page 13: Unified Configuration

    ■ VSP G800 model The VSP G800 is a highly reliable storage system that offers high storage capacity with full redundancy to better protect data and manage storage operations. The storage system consists of a 4U enclosure that includes two controllers and two optional NAS modules.
  • Page 14 4U (174.3 mm) ■ (power supply, contains BNST) DW-F800- ■ DB60C Disk drives The VSP G800 storage system supports the listed disk drive capacities. Chapter 1: Hitachi Virtual Storage Platform G800 hardware overview Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 15 DKC-F810I-6R0H9M LFF disk drive 6 TB DKC-F810I-10RH9M LFF disk drive 10 TB Flash module drives The VSP G800 storage system supports the listed flash module drive capacities. Model number Drive type Drive capacity DKC-F810I-1R6FN 1.75 TB (1.6 TiB) DKC-F810I-3R2FN 3.5 TB (3.2 TiB) DKC-F810I-6R4FN 7 TB (6.4 TiB)
  • Page 16: Features

    Features Model number Drive type Drive capacity DKC-F810I-7R6MGM 7.6 TB Features The features described in the table are included with VSP G800 Feature Value Maximum cache memory supported 512 GB Maximum number of spare drives Maximum number of RAID groups...
  • Page 17: Examples Of Supported Vsp G800 Configurations

    576 HDDs or SSDs 576 FMDs (HAF) 40 FMDs + 2 spares (DC2) 48 FMDs Dense intermix 1440 HDDs or drive tray SSDs Chapter 1: Hitachi Virtual Storage Platform G800 hardware overview Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 18: Chapter 2: Virtual Storage Platform G800 Controller

    Chapter 2: Virtual Storage Platform G800 controller The Virtual Storage Platform G800 model equipped with dual controllers for communicating with a data host. Each controller includes the following internal components such as a processor, dual in- line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator.
  • Page 19: Cblh Front Panel Leds (Without Bezel)

    CBLH front panel LEDs (without bezel) The following table describes the definitions of the CBLH controller front panel LEDs. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 20 Cache flash memory ALM LED (for cache flash Red: Cache flash memory can be removed. memory) CTL ALM LED Red: Controller can be removed. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 21: Cblh Rear Panel

    (for example, BKMF-10 and BKMF-20). CBLH rear panel The following table describes the definitions of the CBLH controller rear panel LEDs. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 22 CBLH rear panel Number Item Power supply unit Front end module Back end module LAN blade Rear view (includes NAS modules) Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 23: Cblh Power Supply Unit Leds And Connectors

    The controllers are equipped with specific interfaces for connecting, powering, configuring, and managing the storage system. The component LEDs display the operating status of the storage system. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 24: Front End Module Descriptions

    Blue: Normal link status. Blink blue: Front end module is in communication status. iSCSI connectors Connect to Ethernet cables. 10-Gbps iSCSI board LEDs and connectors (copper) Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 25 Green: Link connection is established. Blinking: Communication is in progress. Off: No link connection or not ready to communicate. iSCSI connectors Connect to Ethernet cables. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 26: 8-Gbps, 16-Gbps, Or 32-Gbps Fibre Channel (4-Port) Board Leds And Connectors

    Fibre Channel connectors Connect to Fibre Channel cables. STATUS LED Green: Front end module is in power-on state. Red: Front end module can be removed safely. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 27 CHB number Port 1 Port 2 Port 3 Port 4 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 28: 16-Gbps Fibre Channel (2-Port) Board Leds And Connectors

    Blue: Normal link status at 16-Gbps. Green: Normal link status at 4-Gbps or 8-Gbps. Fibre Channel connectors Connect to Fibre Channel cables. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 29: Pcie Module

    16-Gbps Fibre Channel Ports (left to right) CHB number Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H PCIe module Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 30 Gbps) and is linked up normally. Off: PCIe is not linked up (PCIe cable might not be connected). If a PCIe cable is connected, it can be removed safely. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 31: Lan Blade Leds And Connectors

    Red: LAN blade can be removed. Uninterruptible power supply (UPS) port Back end module LEDs and connectors The back end module LEDs display the operating status of the module. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 32 Port LED Blue: Link status is normal. PATH 0 connector Connect to a drive tray. PATH 1 connector Connects to a drive tray. Chapter 2: Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 33: Chapter 3: Drive Trays

    2U (88.2 mm) 2.5 inch (SFF) SFF with front panel bezel Number Item Description POWER LED Green: Drive tray is powered on. READY LED Green: Drive tray is operational. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 34: Sff Front Panel Without Bezel

    Blink green: Drive is being accessed. ALM LED Red: Drive stopped due to a failure and can be replaced. POWER, READY, and LOCATE Green: Drive tray is powered on. LEDs Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 35: Sff Rear Panel

    Green: ENC is in the power- on state. LOCATE LED Amber: Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 36: Sff And Lff Ac Power Supply Unit Leds And Connectors

    Both SFF and LFF drive trays are equipped with AC power supply units. The AC power supply units include LEDs to display its operating status. Number Item Description RDY LED Green: Normal operation. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 37: Sff Power Supply Unit Leds And Connectors

    The following describes the physical specifications of the large form-factor drive tray. Number of Name Model name Height drive slots Drive type DW-F800-DBLC 2U (88.2 mm) 3.5 inch (LFF) Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 38: Lff With Front Panel Bezel

    Locks and unlocks the front panel bezel by using the supplied key. LFF front panel without bezel Number Item Description POWER, READY, and LOCATE Green: Drive tray is LEDs powered on. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 39: Lff Rear Panel

    The slots are organized in the following order: LFF rear panel Number Item Description POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 40: Sff And Lff Ac Power Supply Unit Leds And Connectors

    SFF and LFF AC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with AC power supply units. The AC power supply units include LEDs to display its operating status. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 41: Sff Power Supply Unit Leds And Connectors

    The following describes the physical specifications of the flash module drive tray. Number of Name Model name Height drive slots Drive type DW-F800-DBF 2U (87 mm) Flash module drive (FMD) Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 42: Fmd With Front Panel Bezel

    ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 43: Fmd Front Panel Without Bezel

    Note: ACT indicator is only printed on some types of FMDs. POWER, READY, and LOCATE Green: Drive tray is powered on. LEDs Green: Drive tray is operational. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 44: Fmd Rear Panel

    Green: ENC is in the power- on state. LOCATE LED Amber: Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 45: High-Density Intermix Drive Tray (Db60)

    The following describes the physical specifications of the high-density drive tray. Number of Name Model name Height drive slots Drive type DB60 DW-F800- 4U (176 mm) 3.5 inch (LFF) DB60C Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 46: Dense Intermix Drive Tray With Front Panel Bezel

    ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 47: Dense Intermix Drive Tray Display Leds

    On the left side of the preceding figure, the rear of the drive tray is at the top. Rear of drive tray: 48-59 ■ 36-47 ■ 24-35 ■ 12-23 ■ Front of drive tray: 00-11 ■ Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 48: Dense Intermix Drive Tray Rear Panel

    Blue: IN side port is linked PATH (IN) connector Connects to a controller or drive tray. Console This port is reserved. ALARM LED Red: ENC can be replaced. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 49 Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 50: Chapter 4: Host Port Expansion Chassis

    Green: Host port expansion is turned on. Amber: PCIe module is turned on. Off: PCIe module is turned off. Safety lock Lock or unlock the front bezel. PCIe switchboard Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 51: Host Port Expansion Chassis Fan

    STATUS LED Green: PCIe switchboard is powered on. Red: PCIe switchboard can be replaced safely. Off: PCIe switchboard is powered off. Host port expansion chassis fan Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 52: Pcie Cable Connector

    PCIe cable connector Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. PCIe cable connector Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 53: Host Port Expansion Chassis Power Supply

    Cables can be removed safely. Off: Option PCIe is normal or not set. Host port expansion chassis power supply Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 54 Item Description ALM/RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. AC IN LED Blue: AC input is normal. Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 55: Chapter 5: Nas Module

    Note: The NAS module is not supported on the VSP G200 storage system. NAS Module Ports and LEDs Legend Name Color Description User LAN port This is used with the file level access. Chapter 5: NAS module Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 56 Reserved for future Status LED Green NAS modules are functioning normally. NAS modules can be removed. Link LED Blue Displays link status. Fail LED A failure has occurred. Chapter 5: NAS module Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 57: Chapter 6: Service Processor

    The SVP is also available as a 64-bit software application supplied by Hitachi Vantara. For the latest interoperability updates and details, see the SVP (Service Processor) OS and Hypervisor support for Gx00, Fx00 report at https://support.hitachivantara.com/en_us/...
  • Page 58: Service Processor Description

    Three of the four RJ-45 ports (which connect to the controllers and the IP network) are configured as a bridge. The SVP can be addressed using the default IP address 192.168.0.15. Chapter 6: Service processor Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 59: Svp Front Panel

    Turning on automatic Windows updates or using the manual Windows update ■ method. Installing antivirus software that has been tested and approved by Hitachi. ■ SVP front panel The front panel of the physical SVP is equipped with LEDs, a reset button, and a power button.
  • Page 60: Svp Rear Panel

    Note: After the Initial Startup Wizard is run, the SVP can be used in non- bridge mode. In this mode, the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches. For more information, contact customer support. Chapter 6: Service processor Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 61: Chapter 7: Maintaining The Storage System

    To avoid this situation, charge the battery for more than three hours at least once every six months. Chapter 7: Maintaining the storage system Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 62: Removing Cables

    LAN cable (2). To remove a PCIe cable, pull the tab of the PCIe cable (1) to release the latch and remove the PCIe cable (2). Chapter 7: Maintaining the storage system Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 63: Appendix A: Mechanical Specifications For Vsp G800

    Appendix A: Mechanical specifications for VSP G800 The storage system mechanical specifications are described for VSP G800. VSP G800 mechanical specifications Controller Quantity Component Description CBLH A 4U controller chassis consisting of controllers, channel boards, disk boards, NAS module (optional), AC or DC power supplies, and batteries with cooling fans.
  • Page 64 ENC and AC- DC power supplies equipped with built-in cooling fans. NAS module Component Description NAS module Optional component for block and file storage configuration Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 65 2305.58 GB: 10,000 RPM drive tray - DB60) 3916.14 GB: 7,200 RPM 5874.22 GB: 7,200 RPM 9790.36 GB: 7,200 RPM Only available for DB60/DB60C dense intermix drive tray. Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 66 Up to 75.2º F (24º C) 5 years Up to 86º F (30º C) 5 years Up to 93.2º (34º C) 4 years Up to 104º (40º C) 3 years Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 67 8 Gbps Fibre Channel number of ports (optical) 16 Gbps Fibre Channel (optical) 32 Gbps Fibre Channel (optical) 10 Gbps iSCSI (optical) 10 Gbps iSCSI (copper) Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 68 16 Gbps Fibre Channel Optical (4-port) 32 Gbps Fibre Channel Optical (4-port) 10 Gbps iSCSI (optical) 10 Gbps iSCSI (copper) 10 Gbps Fibre Channel (optical) Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 69 3 TB (or 4 TB when using the LDEVs of other storage systems) Maximum volumes/host groups and iSCSI 2048 targets Maximum volumes/parity groups 2048 Shared memory and data assurance Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 70 (includes the depth of the cable- management arms) Mass The table lists the values of a maximum configuration when all controllers and drives are mounted. Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 71 240 slots per path, the drive is blocked. Cache specifications Item Specification Capacity (GB) NAS module Cache Capacity DDR3 DIMM 8GB x 12 [Slot] Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 72 3 hours every six months. Insulation performance Item Specification Insulation withstand voltage AC 1,500 V (100 mA, 1 min) Insulation resistance DC 500 V, 10 M Ω or more Appendix A: Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 73: Appendix B: Electrical Specifications For Vsp G800

    Dense intermix drive tray: 3460 or less Steady-state power (VA/W) CBLH: 1600/1560 or less SFF drive tray: 480/460 or less LFF drive tray: 380/350 or less Appendix B: Electrical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 74 3. This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. Appendix B: Electrical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 75: Appendix C: Environmental Specifications For Vsp G800

    (°C/h) State Controller FMD drive trays Operating 50°F to 104°F DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is (10°C to 40°C) installed: 50°F to 95°F (10°C to 35°C) Appendix C: Environmental specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 76 5.0 or less at 5 Hz to 300 Hz (no damage to product) 9.8 (1.0 G) Within 5 seconds (resonance point: 10 Hz or less) Transport (packed) 5.0 or less Appendix C: Environmental specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 77 900 (Environmental temperature: 10°C to 40°C) 10°C to 32°C) when DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/ 14RFP drive is installed. (Environmental temperature: 10°C to 40°C) Non-operating -60 to 12,000 Appendix C: Environmental specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 78 32°C or less) (Environmen temperature 32°C or less) temperature 32°C or less) Non- 55 dB 55 dB 71 dB (Environmental opera temperature 32°C or less) ting Appendix C: Environmental specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 79 3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. Appendix C: Environmental specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 80: Appendix D: Iscsi Standards And Specifications

    RFC 1231 MIB II ■ RFC 1757 RMON ■ RFC 1901 SNMPv2 ■ iSCSI specifications Item Specification Comments iSCSI target function Supported iSCSI target function Supported TrueCopy only ® Appendix D: iSCSI standards and specifications Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 81 Maximum transfer unit 1,500, 4,500, 9,000 bytes Jumbo frame, MTU size (MTU) (Ethernet frame) greater than 1500 Link aggregation Not supported Tagged VLAN Supported IPv4 Supported Appendix D: iSCSI standards and specifications Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 82 Subnet mask Supported Gateway address Supported DHCP Ping (ICMP ECHO) Transmit, Supported Receive IPsec TCP port number 3260 Changeable among 1 to 65,535. Observe the Appendix D: iSCSI standards and specifications Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 83 255 per iSCSI port connections at one time CHAP Supported Authentication: login request is sent properly from host to storage. CHAP is not supported during discovery session. Appendix D: iSCSI standards and specifications Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 84 Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar 4. eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef Appendix D: iSCSI standards and specifications Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 85: Appendix E: Replacement Parts

    Replacement period The battery lifetime (intake temperature is 30 degrees C or less.) in the standard environment is as shown below. Appendix E: Replacement parts Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 86: Appendix F: Data And Power Cables

    Serial Attached SCSI (SAS) cables are used to connect drive trays to controllers and other drive trays. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 87 Fibre Channel cable length based on cable size and port speed. Cable size Speed Maximum cable length 9 micron 1 Gbps 3281 feet (1 km) 2 Gbps 6562 feet Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 88 16 Gbps 115 feet (35 meters) 62.5 micron 2 Gbps 328.1 feet (100 meters) 4 Gbps 230 feet (70 meters) 8 Gbps 69 feet (21 meters) Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 89: Fibre Channel Cables

    1. If this combination is specified, the maximum transfer speed automatically specified is 8 Gbps. 2. If this default value is set, Fabric is set to ON automatically. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 90 2. If this default value is set, Fabric is set to ON automatically. Note: The five Hitachi FC HBAs also have an alternate option of Fabric Emulation. When the HBA is configured to use this mode, treat it as an attached switch and set the storage port to Fabric = On and Connection Type = P-to-P.
  • Page 91 114.8 ft (35 m) 328.08 ft (100 410.1 ft (125 m) — 32 Gbps 65.62 ft (20 m) 229.7 ft (70 m) 328.08 ft (100 — Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 92 Wavelength: (OMx) 850 nm LC-LC cable DXLC-2PS- 9/125 μm (longwave) SPC-xxM- Singlemode Wavelength: 10/125-2SR 1300 nm The following figure shows the connector used for optical interfaces. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 93: Iscsi Cables

    Data transfer Single mode rate cable 10 Gbps (FCoE) 269.02 ft (82 m) 984.25 ft (300 1804.46 ft (550 — Cable specifications for iSCSI optical interface Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 94 LC connector type ■ Connector type: LC duplex receptacle connector ■ Interval: 6.25 mm flat type, two rows ■ Cable specifications for 10 Gbps iSCSI copper interface Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 95 50 m 10 Gbps 10GBASE-T STP ( use an RJ-45 LAN cable STP cable that suppresses radio noise) The following figure shows a 10 Gbps iSCSI cable. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 96: Iscsi Standards

    255 (maximum per iSCSI With Linux software port) initiator, the maximum number decreases. Path failover HDLM Supports Microsoft MPIO (Multi Path I/O) Link 10 Gbps SFP+ Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 97 When an iSCSI Port IPv6 is set to Enabled, verify the IPv6 router is connected to the same network, and then set IPv6 global address automatically. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 98 Header digest Supported Detects header error or data error with iSCSI communication. The storage system follows the host's digest setting. If digest is enabled, the performance degrades. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 99: Managing Data Cables

    ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef Managing data cables Organize data cables to protect the integrity of your connections and allow proper airflow around your storage system. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 100 When cabling full-width modules, such as NAS modules as shown in the following figure, route the cables horizontally, so that they do not interfere when replacing a module. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 101: Cable Retention

    Unintentional unplugging or unseating of a power cable can have a serious impact on the operation of an enterprise storage system. Unlike data cables, power connectors do not have built-in retention mechanisms to prevent this from happening. Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 102: Ac Power Cables

    AC power cables Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended.
  • Page 103 South Africa 200-240 10, 16 SABS-164 Switzerland 200-240 SEV 1011 International 200-240 IEC 309 United 200-240 BS-1363 Kingdom International 200-240 IEC 309 International 200-240 IEC 309 Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 104: Ac Connections

    3 IEC 83 NEMA L6-20P 200V-240V 1 ANSI C73.11 2 NEMA 6-15P 3 IEC 83 CEE 7/7 200V-240V 4 CEE (7) II, IV, VII 3 IEC 83 Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 105 AC connections Reference Description Receptacle Input rating standards BS-1363 200V-240V 5 BS 1365 3 IEC 83 AS-3112 200V-240V 6 AS C112 Cable and connector Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 106: Power Cable Usage Guidelines

    Power cable usage guidelines Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: Type of AC line feed provided by the facility.
  • Page 107: Data And Power Cable Model List

    10.0 m, 2-pole power cable with grounding terminal (AC 250 V, 13 A or 15 A-F6516-P620 Power cable for PDU (1) A-F6516-P630 Power cable for PDU (1) Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 108 5 m SAS cable, including omega clips (2) DW-F800-SCQ10A 10 m SAS optical cable DW-F800-SCQ30A 30 m SAS optical cable DW-F800-SCQ1HA 100 m SAS optical cable Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 109 30 m LC-LC optical cable for optical A-6515-JM50L 50 m LC-LC optical cable for optical A-6515-JM100L 100 m LC-LC optical cable for optical A-6515-JM200L 200 m LC-LC optical cable for optical Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 110 Data and power cable model list Model number Specification A-6515-JM300L 300 m LC-LC optical cable for optical Appendix F: Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 111: Appendix G: Port Address Mapping

    VOL. If this problem or other problems occur, revert to the default value of EF. * A value set as the default value. Appendix G: Port address mapping Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 112: Appendix H: Third-Party Racks

    Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack. The following tables list the rail kit information for the specified storage systems.
  • Page 113: Hitachi Universal V2 Rack Accessories

    2. CGR: Corner guide rail kit A3BF-HK-GL-740-1. Hitachi Universal V2 Rack accessories The following table provides rack accessory information for VSP G series storage systems. Table 7 Accessories for the Hitachi Universal V2 Rack Storage system Front door Rear door...
  • Page 114 Third-party rack support for DB60 dense intermix drive trays Appendix H: Third-party racks Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 115: Appendix I: Power Distribution Units For Hitachi Universal V2 Rack

    Appendix I: Power distribution units for Hitachi Universal V2 Rack The Hitachi Universal V2 Rack is equipped with specific power distribution units (PDU) for Americas, APAC, and EMEA regions. The PDUs can provide electrical power to the storage system in a single-phase or three-phase configuration.
  • Page 116: Americas Single-Phase Pdu 1P30A-15C13-3C19Ul.p

    Americas single-phase PDU 1P30A-15C13-3C19UL.P Americas single-phase PDU 1P30A-15C13-3C19UL.P The following figure and table describes the specifications of the PDU. Figure 2 Americas PDU for the Hitachi Universal V2 Rack (Single-phase PDU 1P30A-15C13-3C19UL.P) Part Number Region Phase Description 1P30A-15C13-3C19 Americas Single 208V, 30A (24A ■...
  • Page 117: Americas Three-Phase Pdu 3P30A-15C13-3C19Ul.p

    Americas three-phase PDU 3P30A-15C13-3C19UL.P Figure 3 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-8C13-3C19UL.P) Part Number Region Phase Description 3P30A-8C13-3C19U Americas Three 208V 3P, 30A ■ (24A rated) 60Hz 8 IEC C13 + 3 IEC ■ C19 sockets NEMA L15-30P ■...
  • Page 118: Americas Three-Phase Pdu 3P30A-24C13-6C19Ul.p

    Americas three-phase PDU 3P30A-24C13-6C19UL.P Figure 4 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-15C13-3C19UL.P) Part Number Region Phase Description 3P30A-15C13-3C19 Americas Three 208V 3P, 30A ■ UL.P (24A rated) 60Hz 15 IEC C13 + 3 ■ IEC C19 sockets NEMA L15-30P ■...
  • Page 119: Apac And Emea Single-Phase Pdu 1P32A-9C13-3C19Ce.p

    APAC and EMEA single-phase PDU 1P32A-9C13-3C19CE.P Figure 5 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-24C13-6C19UL.P) Part Number Region Phase Description 3P30A-24C13-6C19 Americas Three 208V 3P, 30A ■ UL.P (24A rated) 60Hz 24 IEC C13 + 6 ■...
  • Page 120: Apac And Emea Single-Phase Pdu 1P32A-18C13-3C19Ce.p

    APAC and EMEA single-phase PDU 1P32A-18C13-3C19CE.P Figure 6 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Single-phase 1P32A-9C13-3C19CE.P) Part Number Region Phase Description 1P32A-9C13-3C19C APAC and EMEA Single 230V max. 32A ■ 50Hz / 60Hz 9 IEC C13 + 3 IEC ■...
  • Page 121: Apac And Emea Three-Phase Pdu 3P16A-9C13-3C19Ce.p

    APAC and EMEA three-phase PDU 3P16A-9C13-3C19CE.P Figure 7 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Single-phase 1P32A-18C13-3C19CE.P) Part Number Region Phase Description 1P32A-18C13-3C19 APAC and EMEA Single 230V max. 32A ■ CE.P 50Hz / 60Hz 18 IEC C13 + 3 ■...
  • Page 122: Apac And Emea Three-Phase Pdu 3P16A-15C13-3C19Ce.p

    APAC and EMEA three-phase PDU 3P16A-15C13-3C19CE.P Figure 8 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three-phase 3P16A-9C13-3C19CE.P) Part Number Region Phase Description 3P16A-9C13-3C19C APAC and EMEA Three 400V max. 3x ■ 16A 50Hz / 60Hz 9 IEC C13 + 3 IEC ■...
  • Page 123: Apac And Emea Three-Phase Pdu 3P32A-24C13-6C19Ce.p

    APAC and EMEA three-phase PDU 3P32A-24C13-6C19CE.P Figure 9 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three-phase 3P16A-15C13-3C19CE.P) Part Number Region Phase Description 3P16A-15C13-3C19 APAC and EMEA Three 400V max. 3x ■ CE.P 16A 50Hz / 60Hz 15 IEC C13 + 3 ■...
  • Page 124 APAC and EMEA three-phase PDU 3P32A-24C13-6C19CE.P Figure 10 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three-phase 3P32A-24C13-6C19CE.P) Part Number Region Phase Description 3P32A-24C13-6C19 APAC and EMEA Three 400V max. 3x ■ CE.P 32A 50Hz / 60Hz 24 IEC C13 + 6 ■...
  • Page 125: Appendix J: Regulatory Compliance

    Appendix J: Regulatory compliance This equipment has been tested and certified for compliance with the following standards. Appendix J: Regulatory compliance Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 126 EN60950-1:2006+A1 TUV Germany IEC60950-1:2005+A All CB countries IEC60950-1:2005+A S-Mark Argentina TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan EN60950-1:2006+A1 CE Radio interference VCCI V-3/2013.04 VCCI Japan voluntary control Appendix J: Regulatory compliance Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 127: Appendix K: Safety And Environmental Notices

    Japan. or both. Contact the Hitachi Legal Department for guidance about any export compliance questions. Backup Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize chances for data loss. Data backup is also critical when hardware components are added or replaced, because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems.
  • Page 128 This is a class A product. In a domestic environment this product can cause radio interference in which case the user can be required to take adequate measures. Appendix K: Safety and environmental notices Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 129: Index

    LEDS on dense intermix drive tray drive chassis cables AC power LEDs Fibre Channel power supply iSCSI drive trays managing dense intermix removing flash module required large form-factor retention 101, maximum number CBLH controller small form-factor Index Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 130 LEDs PCIe module power supply PCIe switchboard physical SVP rear panel interconnect adapter Port Fibre Channel address mapping iSCSI ports PCIe board power cable iSCSI power cable assemblies Index Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 131 SAS cables removing scalability server service processor 57, side panels small form factor drive tray AC power supply unit 36, DC power supply units 37, rear panel with front panel bezel Index Hitachi Virtual Storage Platform G800 Hardware Reference Guide...
  • Page 132 Hitachi Vantara Corporation Corporate Headquarters Regional Contact Information 2845 Lafayette Street Americas: +1 866 374 5822 or info@hitachivantara.com Santa Clara, CA 95050-2639 USA Europe, Middle East, and Africa: +44 (0) 1753 618000 or info@emea@hitachivantara.com www.HitachiVantara.com | community.HitachiVantara.com Asia Pacific: + 852 3189 7900 or info.marketing.apac@hitachivantara.com...

Table of Contents