Sense
Detailed
code
code
9608
0015
9608
0016
9608
0017
9608
0018
9608
0019
9608
001A
9608
001B
9608
001D
9608
001E
9608
001F
9608
0020
9608
0021
9608
0022
9608
0023
9608
0028
9608
0029
9608
002A
9608
002B
9608
002C
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
Table 3-5: Sense Codes (Continued)
Sub
Error contents
code
84
The data pool LU being used is in a
status other than normal or
regressive.
84
There is no V-VOL corresponding
to the specified P-VOL.
84
The pair attribute of the P-VOL is
V-VOL.
84
The pair attribute of the V-VOL is
P-VOL.
84
The object LUN is not the same as
the expected one.
84
The same MU number was
specified within the same P-VOL.
84
The process is in progress.
84
The object LUN is not the same as
the expected one.
84
The specified V-VOL is not
specified to be grouped. (Group ID
suspension)
84
The V-VOL, which is an object of
the batch suspension, is in a status
other than PAIR. (Group ID
suspension)
84
The process is in progress.
84
The process is in progress.
84
The pair status of the V-VOL is
illegal.
84
The object LUN is not the same as
the expected one.
84
The specified MU number is
different from that of the specified
V-VOL.
84
The specified MU number is
different from that of the specified
V-VOL.
84
The specified MU number is
different from that of the specified
V-VOL.
84
The pair status was changed to
PSUE because the process
terminated abnormally.
84
The specified P-VOL has excess
pinned data (at the time of a
restoration only).
Maintenance log and tracing functions
Recommended Action
Check the status of the pool
LU.
Check the status of the LU.
Check the status of the LU.
Check the status of the LU.
Check the specified LU.
Make sure of the specified MU
number.
Retry after waiting for a
while.
Check the specified LU.
Check the pair attribute of
the LU.
Check the pair status of the
LU.
Retry after waiting for a
while.
Retry after waiting for a
while.
Check the pair status of the
LU.
Check the specified LU.
Make sure of the specified MU
number.
Make sure of the specified MU
number.
Make sure of the specified MU
number.
Place the pair concerned in
the SMPL status once, and
then create the pair again.
Retry after eliminating
pinned data.
3–25