Hitachi AMS 2000 Reference Manual page 178

Adaptable modular storage/family command control interface (cci)
Hide thumbs Also See for AMS 2000:
Table of Contents

Advertisement

Sense
Detailed
code
code
9576
x0C0
9576
x0C1
9576
x0C2
9576
x0C4
9576
x0C6
9576
x0C7
9576
x0CA
9576
x0CB
9576
x0CF
9576
x0D1
9576
x0D2
9576
x0D3
9576
x0D4
9576
x0D7
3–22
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
Table 3-5: Sense Codes (Continued)
Sub
Error contents
code
94
The S-VOL in the remote array
does not exist on the default
owner controller and, at the same
time, it is making the drive spun
up.
94
The S-VOL in the remote array
does not exist on the default
owner controller and, at the same
time, it is making the system copy.
94
The S-VOL in the remote array
does not exist on the default
owner controller and, at the same
time, it is writing the takeover
information.
94
When a new pair of a CTG is
created, the cycle time that has
been set for the local and remote
array is less than the minimum
interval.
94
The specified S-VOL is undergoing
the migration.
94
The specified S-VOL is the
reserved LU.
94
The specified S-VOL is undergoing
the migration.
94
The specified S-VOL is the
reserved LU.
94
The disk drives that configure a
RAID group, to which a target LU
in the remote array belongs have
been spun down.
94
The disk drives that configure a
RAID group, to which a target LU
in the remote array belongs have
been spun down.
94
The S-VOL pool number in the
remote array is not same as the
one that is being used for
SnapShot.
94
The license validity of the remote
array is expired.
94
The S-VOL pair attribute in the
remote array is P-VOL.
94
The indicated S-VOL is not PSUS
status in the ShadowImage pair.
Maintenance log and tracing functions
Recommended Action
Check the status of the
remote array and retry after
waiting for a while.
Check the status of the
remote array and retry after
waiting for a while.
Check the status of the
remote array and retry after
waiting for a while.
Check the cycle time that has
been set for the local and
remote array.
Re-execute the migration
after splitting the pair.
Re-execute the migration
specifying an LU other than
the reserved LU for the 
S-VOL.
Re-execute the migration
after splitting the pair.
Re-execute the migration
specifying an LU other than
the reserved LU for the 
S-VOL.
Perform the operation again
after spinning up the disk
drives that configure the
RAID group.
Perform the operation again
after spinning up the disk
drives that configure the
RAID group.
Confirm the indicated pool
number in the remote array.
Purchase the license.
Check the LU status of the
remote array.
Execute again after having
the ShadowImage pair status
in the remote array be PSUS
or SMPL.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents