APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 39 of 65)
ADDR
REGISTER NAME
8E0A
...Repeated for Digital Element 48
Trip Bus (Read/Write Setting) (6 modules)
8ED0
Trip Bus 1 Function
8ED1
Trip Bus 1 Block
8ED3
Trip Bus 1 Pickup Delay
8ED4
Trip Bus 1 Reset Delay
8ED5
Trip Bus 1 Input (16 items)
8EF5
Trip Bus 1 Latching
8EF6
Trip Bus 1 Reset
8EF8
Trip Bus 1 Target
8EF9
Trip Bus 1 Events
8EFA
Reserved (8 items)
8F02
...Repeated for Trip Bus 2
8F34
...Repeated for Trip Bus 3
8F66
...Repeated for Trip Bus 4
8F98
...Repeated for Trip Bus 5
8FCA
...Repeated for Trip Bus 6
FlexElement (Read/Write Setting) (16 modules)
9000
FlexElement 1 Function
9001
FlexElement 1 Name
9004
FlexElement 1 InputP
9005
FlexElement 1 InputM
9006
FlexElement 1 Compare
9007
FlexElement 1 Input
9008
FlexElement 1 Direction
9009
FlexElement 1 Hysteresis
900A
FlexElement 1 Pickup
900C
FlexElement 1 DeltaT Units
900D
FlexElement 1 DeltaT
900F
FlexElement 1 Pickup Delay
9010
FlexElement 1 Reset Delay
9011
FlexElement 1 Block
9013
FlexElement 1 Target
9014
FlexElement 1 Events
9015
...Repeated for FlexElement 2
902A
...Repeated for FlexElement 3
903F
...Repeated for FlexElement 4
9054
...Repeated for FlexElement 5
9069
...Repeated for FlexElement 6
907E
...Repeated for FlexElement 7
9093
...Repeated for FlexElement 8
90A8
...Repeated for FlexElement 9
90BD
...Repeated for FlexElement 10
90D2
...Repeated for FlexElement 11
90E7
...Repeated for FlexElement 12
90FC
...Repeated for FlexElement 13
9111
...Repeated for FlexElement 14
9126
...Repeated for FlexElement 15
913B
...Repeated for FlexElement 16
DCmA Outputs (Read/Write Setting) (24 modules)
9360
DCmA Output 1 Source
9361
DCmA Output 1 Range
9362
DCmA Output 1 Minimum
9364
DCmA Output 1 Maximum
GE Multilin
0 to 4294967295
0 to 4294967295
0 to 4294967295
20 to 86400
0 to 65.535
0 to 65.535
0 to 4294967295
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
0 to 1
---
1
---
1
0 to 600
s
0.01
0 to 600
s
0.01
---
1
0 to 1
---
1
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
---
---
---
0 to 65535
---
1
0 to 65535
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0.1 to 50
%
0.1
-90 to 90
pu
0.001
0 to 2
---
1
---
1
s
0.001
s
0.001
---
1
0 to 2
---
1
0 to 1
---
1
0 to 65535
---
1
0 to 2
---
1
–90 to 90
pu
0.001
–90 to 90
pu
0.001
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F102
0 (Disabled)
F300
0
F001
0
F001
0
F300
0
F102
0 (Disabled)
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F206
"FxE 1"
F600
0
F600
0
F516
0 (LEVEL)
F515
0 (SIGNED)
F517
0 (OVER)
F001
30
F004
1000
F518
0 (Milliseconds)
F003
20
F001
0
F001
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F600
0
F522
0 (–1 to 1 mA)
F004
0
F004
1000