APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 25 of 65)
ADDR
REGISTER NAME
4369
Total Mismatches Port B
436B
Total Errors
IPv4 Route Table (Read/Write Setting) (6 modules)
4370
IPv4 Network Route 1 Destination
4372
IPv4 Network Route 1 Netmask
4374
IPv4 Network Route 1 Gateway
4376
...Repeated for Route 2
437C
...Repeated for Route 3
4382
...Repeated for Route 4
4388
...Repeated for Route 5
438E
...Repeated for Route 6
Installation (Read/Write Setting)
43E0
Relay Programmed State
43E1
Relay Name
User Programmable Self Tests (Read/Write Setting)
4441
User Programmable Detect Ring Break Function
4442
User Programmable Direct Device Off Function
4443
User Programmable Remote Device Off Function
4444
User Programmable First Ethernet Fail Function
4445
User Programmable Secondary Ethernet Fail Function
4446
User Programmable Battery Fail Function
4447
User Programmable SNTP Fail Function
4448
User Programmable IRIG-B Fail Function
4449
User Programmable Ethernet Switch Fail Function
444A
Process Bus Failure Operand
444C
PTP Fail Function
444D
User Programmable Third Ethernet Fail Function
444E
User Programmable SFP Fail Function
CT Settings (Read/Write Setting) (6 modules)
4480
Phase CT 1 Primary
4481
Phase CT 1 Secondary
4482
Ground CT 1 Primary
4483
Ground CT 1 Secondary
4484
...Repeated for CT Bank 2
4488
...Repeated for CT Bank 3
448C
...Repeated for CT Bank 4
4490
...Repeated for CT Bank 5
4494
...Repeated for CT Bank 6
VT Settings (Read/Write Setting) (6 modules)
4500
Phase VT 1 Connection
4501
Phase VT 1 Secondary
4502
Phase VT 1 Ratio
4504
Auxiliary VT 1 Connection
4505
Auxiliary VT 1 Secondary
4506
Auxiliary VT 1 Ratio
4508
...Repeated for VT Bank 2
4510
...Repeated for VT Bank 3
4518
...Repeated for VT Bank 4
4520
...Repeated for VT Bank 5
4528
...Repeated for VT Bank 6
Source Settings (Read/Write Setting) (6 modules)
4580
Source 1 Name
4583
Source 1 Phase CT
GE Multilin
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
---
1
---
1
---
1
---
1
---
1
0 to 1
---
1
---
---
---
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
1 to 65000
A
1
0 to 1
---
1
1 to 65000
A
1
0 to 1
---
1
0 to 1
---
1
25 to 240
V
0.1
1 to 24000
:1
1
0 to 6
---
1
25 to 240
V
0.1
1 to 24000
:1
1
0 to 1
---
1
0 to 63
---
1
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F003
0
F003
0
F003
2130706433
F003
4278190080
F003
2130706433
F133
0 (Not
Programmed)
F202
"Relay-1"
F102
1 (Enabled)
F102
1 (Enabled)
F102
1 (Enabled)
F102
0 (Disabled)
F102
0 (Disabled)
F102
1 (Enabled)
F102
1 (Enabled)
F102
1 (Enabled)
F102
1 (Enabled)
F300
0
F102
1 (Enabled)
F102
0 (Disabled)
F102
0 (Disabled)
F001
1
F123
0 (1 A)
F001
1
F123
0 (1 A)
F100
0 (Wye)
F001
664
F060
1
F166
1 (Vag)
F001
664
F060
1
F206
"SRC 1"
F400
0
B-33