GE C70 Instruction Manual page 560

Capacitor bank protection and control system ur series
Hide thumbs Also See for C70:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 32 of 65)
ADDR
REGISTER NAME
5F94
Setting Group 2 Name
5F9C
Setting Group 3 Name
5FA4
Setting Group 4 Name
5FAC
Setting Group 5 Name
5FB4
Setting Group 6 Name
B
Negative Sequence Time Overcurrent (Read/Write Grouped Setting) (2 modules)
6300
Negative Sequence Time Overcurrent 1 Function
6301
Negative Sequence Time Overcurrent 1 Signal Source
6302
Negative Sequence Time Overcurrent 1 Pickup
6303
Negative Sequence Time Overcurrent 1 Curve
6304
Negative Sequence Time Overcurrent 1 Multiplier
6305
Negative Sequence Time Overcurrent 1 Reset
6306
Negative Sequence Time Overcurrent 1 Block
6308
Negative Sequence Time Overcurrent 1 Target
6309
Negative Sequence Time Overcurrent 1 Events
630A
Reserved (7 items)
6311
...Repeated for Negative Sequence Time Overcurrent 2
Capacitor Bank Overvoltage Settings (Read/Write Grouped Setting) (3 modules)
6330
Bank Phase Overvoltage 1 Function
6331
Bank Phase Overvoltage 1 Bus Source
6332
Bank Phase Overvoltage 1 Neutral Source
6333
Bank Phase Overvoltage 1 Bank Ground
6334
Bank Phase Overvoltage 1 Curve
6335
Bank Phase Overvoltage 1 Curve Time Multiplier
6336
Bank Phase Overvoltage 1 Stage 1A Pickup
6337
Bank Phase Overvoltage 1 Stage 2A Pickup
6338
Bank Phase Overvoltage 1 Stage 3A Pickup
6339
Bank Phase Overvoltage 1 Stage 4A Pickup
633A
Bank Phase Overvoltage 1 Stage 1B Pickup
633B
Bank Phase Overvoltage 1 Stage 2B Pickup
633C
Bank Phase Overvoltage 1 Stage 3B Pickup
633D
Bank Phase Overvoltage 1 Stage 4B Pickup
633E
Bank Phase Overvoltage 1 Stage 1C Pickup
633F
Bank Phase Overvoltage 1 Stage 2C Pickup
6340
Bank Phase Overvoltage 1 Stage 3C Pickup
6341
Bank Phase Overvoltage 1 Stage 4C Pickup
6342
Bank Phase Overvoltage 1 Stage 1 Pickup Delay
6343
Bank Phase Overvoltage 1 Stage 2 Pickup Delay
6344
Bank Phase Overvoltage 1 Stage 3 Pickup Delay
6345
Bank Phase Overvoltage 1 Dropout Delay
6346
Bank Phase Overvoltage 1 Block
6348
Bank Phase Overvoltage 1 Target
6349
Bank Phase Overvoltage 1 Events
634A
...Repeated for Bank Phase Overvoltage 2
6364
...Repeated for Bank Phase Overvoltage 3
Capacitor Bank Overvoltage Actuals (Read Only) (3 modules)
6390
Bank Overvoltage 1 Phase A Operate Voltage
6391
Bank Overvoltage 1 Phase B Operate Voltage
6392
Bank Overvoltage 1 Phase C Operate Voltage
6393
...Repeated for Bank Overvoltage 2
6396
...Repeated for Bank Overvoltage 3
Negative Sequence Instantaneous Overcurrent (Read/Write Grouped Setting) (2 modules)
63C0
Negative Sequence Instantaneous OC 1 Function
63C1
Negative Sequence Instantaneous OC 1 Signal Source
B-40
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 65.535
0 to 65.535
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0 to 1
---
1
0 to 5
---
1
0 to 30
pu
0.001
0 to 16
---
1
0 to 600
---
0.01
0 to 1
---
1
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 5
---
1
0 to 2
---
1
0 to 3
---
1
1 to 10
---
0.01
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0.8 to 2
pu
0.001
0 to 600
s
0.01
0 to 600
s
0.01
0 to 600
s
0.01
0 to 600
s
0.01
---
1
0 to 2
---
1
0 to 1
---
1
pu
0.001
pu
0.001
pu
0.001
0 to 1
---
1
0 to 5
---
1
APPENDIX B
FORMAT
DEFAULT
F203
(none)
F203
(none)
F203
(none)
F203
(none)
F203
(none)
F102
0 (Disabled)
F167
0 (SRC 1)
F001
1000
F103
0 (IEEE Mod Inv)
F001
100
F104
0 (Instantaneous)
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
F167
0 (SRC 1)
F093
0 (Grounded)
F094
0 (FlexCurve A)
F001
100
F001
1050
F001
1100
F001
1200
F001
1050
F001
1050
F001
1100
F001
1200
F001
1050
F001
1050
F001
1100
F001
1200
F001
1050
F001
6000
F001
1000
F001
200
F001
25
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F001
0
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents