B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 26 of 65)
ADDR
REGISTER NAME
4584
Source 1 Ground CT
4585
Source 1 Phase VT
4586
Source 1 Auxiliary VT
4587
...Repeated for Source 2
458E
...Repeated for Source 3
B
4595
...Repeated for Source 4
459C
...Repeated for Source 5
45A3
...Repeated for Source 6
Power System (Read/Write Setting)
4600
Nominal Frequency
4601
Phase Rotation
4602
Frequency and Phase Reference
4603
Frequency Tracking Function
Breaker Control (Read/Write Settings) (6 modules)
47D0
Breaker 1 Function
47D1
Breaker 1 Name
47D4
Breaker 1 Mode
47D5
Breaker 1 Open
47D7
Breaker 1 Close
47D9
Breaker 1 Phase A / Three-pole Closed
47DB
Breaker 1 Phase B Closed
47DD
Breaker 1 Phase C Closed
47DF
Breaker 1 External Alarm
47E1
Breaker 1 Alarm Delay
47E3
Breaker 1 Pushbutton Control
47E4
Breaker 1 Manual Close Recall Time
47E6
Breaker 1 Out of Service
47E8
Breaker 1 Block Open
47EA
Breaker 1 Block Close
47EC
Breaker 1 Phase A / Three-pole Opened
47EE
Breaker 1 Phase B Opened
47F0
Breaker 1 Phase C Opened
47F2
Breaker 1 Operate Time
47F3
Breaker 1 Events
47F4
Reserved
47F5
...Repeated for Breaker 2
481A
...Repeated for Breaker 3
483F
...Repeated for Breaker 4
4864
...Repeated for Breaker 5
4889
...Repeated for Breaker 6
FlexCurves A and B (Read/Write Settings)
4910
FlexCurve A (120 items)
4988
FlexCurve B (120 items)
Modbus User Map (Read/Write Setting)
4A00
Modbus Address Settings for User Map (256 items)
User Displays Settings (Read/Write Setting) (16 modules)
4C00
User-Definable Display 1 Top Line Text
4C0A
User-Definable Display 1 Bottom Line Text
4C14
Modbus Addresses of Display 1 Items (5 items)
4C19
Reserved (7 items)
4C20
...Repeated for User-Definable Display 2
4C40
...Repeated for User-Definable Display 3
4C60
...Repeated for User-Definable Display 4
4C80
...Repeated for User-Definable Display 5
B-34
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
0 to 63
---
1
0 to 63
---
1
0 to 63
---
1
25 to 60
Hz
1
0 to 1
---
1
0 to 5
---
1
0 to 1
---
1
0 to 1
---
1
---
---
---
0 to 1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
s
0.001
0 to 1
---
1
s
0.001
---
1
---
1
---
1
---
1
---
1
---
1
s
0.001
0 to 1
---
1
s
1
ms
1
ms
1
---
1
---
---
---
---
---
---
---
1
---
---
---
APPENDIX B
FORMAT
DEFAULT
F400
0
F400
0
F400
0
F001
60
F106
0 (ABC)
F167
0 (SRC 1)
F102
1 (Enabled)
F102
0 (Disabled)
F206
"Bkr 1"
F157
0 (3-Pole)
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F003
0
F102
0 (Disabled)
F003
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F001
70
F102
0 (Disabled)
F001
0
F011
0
F011
0
F001
0
F202
" "
F202
" "
F001
0
F001
0
GE Multilin