5 SETTINGS
Table 5–15: C70 FLEXLOGIC OPERANDS (Sheet 4 of 10)
OPERAND TYPE
OPERAND SYNTAX
ELEMENT:
CUR BAL 1 STG1A PKP
Phase current
CUR BAL 1 STG1B PKP
unbalance
CUR BAL 1 STG1C PKP
CUR BAL 1 STG2A PKP
CUR BAL 1 STG2B PKP
CUR BAL 1 STG2C PKP
CUR BAL 1 STG3A PKP
CUR BAL 1 STG3B PKP
CUR BAL 1 STG3C PKP
CUR BAL 1 STG4A PKP
CUR BAL 1 STG4B PKP
CUR BAL 1 STG4C PKP
CUR BAL 1 PKP A
CUR BAL 1 PKP B
CUR BAL 1 PKP C
CUR BAL 1 PKP
CUR BAL 1 DPO
CUR BAL 1 STG1A OP
CUR BAL 1 STG1B OP
CUR BAL 1 STG1C OP
CUR BAL 1 STG2A OP
CUR BAL 1 STG2B OP
CUR BAL 1 STG2C OP
CUR BAL 1 STG3A OP
CUR BAL 1 STG3B OP
CUR BAL 1 STG3C OP
CUR BAL 1 STG4A OP
CUR BAL 1 STG4B OP
CUR BAL 1 STG4C OP
CUR BAL 1 OP A
CUR BAL 1 OP B
CUR BAL 1 OP C
CUR BAL 1 OP
CUR BAL 2 to 3
ELEMENT:
DAY SUNDAY
Time of day timer
DAY MONDAY
day
DAY TUESDAY
DAY WEDNESDAY
DAY THURSDAY
DAY FRIDAY
DAY SATURDAY
ELEMENT:
Dig Element 1 PKP
Digital elements
Dig Element 1 OP
Dig Element 1 DPO
Dig Element 2 to 48
ELEMENT:
FxE 1 PKP
FlexElements
FxE 1 OP
FxE 1 DPO
FxE 2 to 16
ELEMENT:
GROUND IOC1 PKP
Ground
GROUND IOC1 OP
instantaneous
GROUND IOC1 DPO
overcurrent
GROUND IOC2 to 12
ELEMENT:
GROUND TOC1 PKP
Ground time
GROUND TOC1 OP
overcurrent
GROUND TOC1 DPO
GROUND TOC2 to 6
ELEMENT
LATCH 1 ON
Non-volatile latches
LATCH 1 OFF
LATCH 2 to 16
GE Multilin
OPERAND DESCRIPTION
Phase current unbalance element 1 picked up in phase A of stage 1
Phase current unbalance element 1 picked up in phase B of stage 1
Phase current unbalance element 1 picked up in phase C of stage 1
Phase current unbalance element 1 picked up in phase A of stage 2
Phase current unbalance element 1 picked up in phase B of stage 2
Phase current unbalance element 1 picked up in phase C of stage 2
Phase current unbalance element 1 picked up in phase A of stage 3
Phase current unbalance element 1 picked up in phase B of stage 3
Phase current unbalance element 1 picked up in phase C of stage 3
Phase current unbalance element 1 picked up in phase A of stage 4
Phase current unbalance element 1 picked up in phase B of stage 4
Phase current unbalance element 1 picked up in phase C of stage 4
Phase current unbalance element 1 picked up in phase A
Phase current unbalance element 1 picked up in phase B
Phase current unbalance element 1 picked up in phase C
Phase current unbalance element 1 picked up
Phase current unbalance element 1 dropped out
Phase current unbalance element 1 operated in phase A of stage 1
Phase current unbalance element 1 operated in phase B of stage 1
Phase current unbalance element 1 operated in phase C of stage 1
Phase current unbalance element 1 operated in phase A of stage 2
Phase current unbalance element 1 operated in phase B of stage 2
Phase current unbalance element 1 operated in phase C of stage 2
Phase current unbalance element 1 operated in phase A of stage 3
Phase current unbalance element 1 operated in phase B of stage 3
Phase current unbalance element 1 operated in phase C of stage 3
Phase current unbalance element 1 operated in phase A of stage 4
Phase current unbalance element 1 operated in phase B of stage 4
Phase current unbalance element 1 operated in phase C of stage 4
Phase current unbalance element 1 operated in phase A
Phase current unbalance element 1 operated in phase B
Phase current unbalance element 1 operated in phase C
Phase current unbalance element 1 operated
Same set of operands as shown for CUR BAL 1
Current day is Sunday
Current day is Monday
Current day is Tuesday
Current day is Wednesday
Current day is Thursday
Current day is Friday
Current day is Saturday
Digital Element 1 is picked up
Digital Element 1 is operated
Digital Element 1 is dropped out
Same set of operands as shown for Dig Element 1
FlexElement 1 has picked up
FlexElement 1 has operated
FlexElement 1 has dropped out
Same set of operands as shown for FxE 1
Ground instantaneous overcurrent 1 has picked up
Ground instantaneous overcurrent 1 has operated
Ground instantaneous overcurrent 1 has dropped out
Same set of operands as shown for GROUND IOC 1
Ground time overcurrent 1 has picked up
Ground time overcurrent 1 has operated
Ground time overcurrent 1 has dropped out
Same set of operands as shown for GROUND TOC1
Non-volatile latch 1 is ON (Logic = 1)
Non-volatile latch 1 is OFF (Logic = 0)
Same set of operands as shown for LATCH 1
C70 Capacitor Bank Protection and Control System
5.5 FLEXLOGIC