APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 47 of 65)
ADDR
REGISTER NAME
AA03
IEC 61850 GOOSE Analog Input 1 Units
AA05
IEC 61850 GOOSE Analog Input 1 Per-Unit Base
AA07
...Repeated for IEC 61850 GOOSE Analog Input 2
AA0E
...Repeated for IEC 61850 GOOSE Analog Input 3
AA15
...Repeated for IEC 61850 GOOSE Analog Input 4
AA1C
...Repeated for IEC 61850 GOOSE Analog Input 5
AA23
...Repeated for IEC 61850 GOOSE Analog Input 6
AA2A
...Repeated for IEC 61850 GOOSE Analog Input 7
AA31
...Repeated for IEC 61850 GOOSE Analog Input 8
AA38
...Repeated for IEC 61850 GOOSE Analog Input 9
AA3F
...Repeated for IEC 61850 GOOSE Analog Input 10
AA46
...Repeated for IEC 61850 GOOSE Analog Input 11
AA4D
...Repeated for IEC 61850 GOOSE Analog Input 12
AA54
...Repeated for IEC 61850 GOOSE Analog Input 13
AA5B
...Repeated for IEC 61850 GOOSE Analog Input 14
AA62
...Repeated for IEC 61850 GOOSE Analog Input 15
AA69
...Repeated for IEC 61850 GOOSE Analog Input 16
AA70
...Repeated for IEC 61850 GOOSE Analog Input 17
AA77
...Repeated for IEC 61850 GOOSE Analog Input 18
AA7E
...Repeated for IEC 61850 GOOSE Analog Input 19
AA85
...Repeated for IEC 61850 GOOSE Analog Input 20
AA8C
...Repeated for IEC 61850 GOOSE Analog Input 21
AA93
...Repeated for IEC 61850 GOOSE Analog Input 22
AA9A
...Repeated for IEC 61850 GOOSE Analog Input 23
AAA1
...Repeated for IEC 61850 GOOSE Analog Input 24
AAA8
...Repeated for IEC 61850 GOOSE Analog Input 25
AAAF
...Repeated for IEC 61850 GOOSE Analog Input 26
AAB6
...Repeated for IEC 61850 GOOSE Analog Input 27
AABD
...Repeated for IEC 61850 GOOSE Analog Input 28
AAC4
...Repeated for IEC 61850 GOOSE Analog Input 29
AACB
...Repeated for IEC 61850 GOOSE Analog Input 30
AAD2
...Repeated for IEC 61850 GOOSE Analog Input 31
AAD9
...Repeated for IEC 61850 GOOSE Analog Input 32
IEC 61850 XCBR Configuration (Read/Write Settings and Commands) (6 modules)
AB00
Operand for IEC 61850 XCBR1.ST.Loc status
AB02
Command to Clear XCBR1 OpCnt (Operation Counter
AB03
Operand for IEC 61850 XCBR Check Sync Release
AB05
Operand for IEC 61850 XCBR Open Interlock
AB07
Operand for IEC 61850 XCBR Close Interlock
AB09
Operand for IEC 61850 XCBR Pos ct1Model
AB0A
Operand for IEC 61850 XCBR Pos sboTimeout
AB0B
...Repeated for Module 2
AB16
...Repeated for Module 3
AB21
...Repeated for Module 4
AB2C
...Repeated for Module 5
AB37
...Repeated for Module 6
IEC 61850 LN Name Prefixes (Read/Write Settings)
AB48
IEC 61850 Logical Node LPHD1 Name Prefix
AB4B
IEC 61850 Logical Node PIOCx Name Prefix (72 items)
AC23
IEC 61850 Logical Node PTOCx Name Prefix (24 items)
AC6B
IEC 61850 Logical Node PTUVx Name Prefix (13 items)
AC92
IEC 61850 Logical Node PTOVx Name Prefix (10 items)
ACB6
IEC 61850 Logical Node PDISx Name Prefix (10 items)
GE Multilin
0 to 999999999.999
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
---
---
---
---
0.001
---
1
0 to 1
---
1
---
1
---
1
---
1
0 to 4
---
1
2 to 60
s
1
0 to 65534
---
1
0 to 65534
---
1
0 to 65534
---
1
0 to 65534
---
1
0 to 65534
---
1
0 to 65534
---
1
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F207
(none)
F060
1
F300
0
F126
0 (No)
F300
0
F300
0
F300
0
F001
2
F001
30
F206
(none)
F206
(none)
F206
(none)
F206
(none)
F206
(none)
F206
(none)
B-55