Selecting forward and reverse runs (operation panel only)


• Function
Program the direction of rotation of the motor when the running and stopping are made using the RUN key and
STOP key on the operation panel. Valid when  (command mode selection) = (operation panel input).
[Parameter setting]
Title

Check the direction of rotation on the status monitor.
: Forward run
 For monitoring, refer to Section 8.1.
When the F and R terminals are used for switching between forward run and stop from the terminal board, the 
forward/reverse run selection parameter is rendered invalid.
If F and CC, as well as R and CC are connected at the same time: Stop (Default setting)
Use the parameter  to select between reverse run and stop in this case.
 For more details, refer to Section 6.2.1.
This function is valid only when  is set at  (Operation panel input enabled).
To switch between forward run and reverse run from the control panel with parameter  set to  or , perform
these steps: to switch to forward run, press the
reverse run, press the


0
Example of 7-step speed operation
: Forward/reverse run selection
Function
Forward/reverse run selection
: Reverse run
Short across the F-CC terminals: forward run
Short across the R-CC terminals: reverse run
key while holding



Adjustment range
: Forward run
: Reverse run
: Forward run (F/R switching possible)
: Reverse run (F/R switching possible)
ENT
key while holding the
key down.
ENT
E-20
E6581386


Time
[s]
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Default setting
key down, or to switch to