[4] Terminal response time setup
Communi
Title
cation
Function
No.
Output terminal function selection 10 (R3)
0168

*1
Output terminal function selection 11 (R4)
0169

*1
0170
Base frequency 2


0171
Base frequency voltage 2

0172
Manual torque boost 2

0173
Thermal protection level 2
*1: Unsupported option
*2:  For the adjustment range, see the table on page K-39.
*3: Default values vary depending on the capacity.  See the table of K-42.
*4: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
[5] V/f 5-point setting
Communi
Title
cation
Function
No.

0190
V/f 5-point setting VF1 frequency
0191
V/f 5-point setting VF1 voltage

0192
V/f 5-point setting VF2 frequency


0193
V/f 5-point setting VF2 voltage

0194
V/f 5-point setting VF3 frequency
0195
V/f 5-point setting VF3 voltage


0196
V/f 5-point setting VF4 frequency

0197
V/f 5-point setting VF4 voltage
0198
V/f 5-point setting VF5 frequency

0199
V/f 5-point setting VF5 voltage

[6] Speed/torque reference gain/bias setup [1/3]
Communi
Title
cation
Function
No.
0200
Frequency priority selection

0201
VI/II input point 1 setting


0202
VI/II input point 1 frequency
Adjustment range
0~255 *2
0~255 *2
25.0~500.0 Hz
50~330V/660V
0.0~30.0%
10~100%
Adjustment range
0.0~ Hz
0.0~100.0%
0.0~ Hz
0.0~100.0%
0.0~ Hz
0.0~100.0%
0.0~ Hz
0.0~100.0%
0.0~ Hz
0.0~100.0%
Adjustment range
0:/ terminal switching (input
terminal function selection 104, 105)
1:/ frequency switching (switching
with )
0~100%
0.0~ Hz
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
254
Disabled
●/●
1/1
254
Disabled
●/●
0.1/0.01
*4
Disabled
-
1/0.1
*3
Disabled
-
0.1/0.1
*3
Enabled
-
1/1
100
Enabled
-
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
0.1/0.01
0.0
Disabled
-
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
Write during
setting unit
Default
Vector
running
(Panel/Communi
setting
control
cation)
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
PM
V/f
Reference
control
7. 2. 2
7. 2. 2
-
6. 4. 1
-
6. 4. 1
-
6. 4. 1
-
6. 4. 1
PM
V/f
Reference
control
-
5. 6
-
5. 6
-
5. 6
-
5. 6
-
5. 6
-
5. 6
-
5. 6
-
5. 6
-
5. 6
-
5. 6
PM
V/f
Reference
control
6. 6. 1
7. 3. 2
7. 3. 2