Toshiba TOSVERT VF-PS1 Instruction Manual page 244

Variable torque inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

Selection table of separate-type options (2/2)
Appli
Voltage
-cable
Inverter
class
motor
model
[kW]
0.4
VFPS1-2004PL
0.75
VFPS1-2007PL
1.5
VFPS1-2015PL
2.2
VFPS1-2022PL
3.7
VFPS1-2037PL
5.5
VFPS1-2055PL
7.5
VFPS1-2075PL
11
VFPS1-2110PM
200V
15
VFPS1-2150PM
class
18.5
VFPS1-2185PM
22
VFPS1-2220PM
30
VFPS1-2300PM
37
VFPS1-2370PM
45
VFPS1-2450PM
55
VFPS1-2550P
75
VFPS1-2750P
90
VFPS1-2900P
0.75
VFPS1-4007PL
1.5
VFPS1-4015PL
2.2
VFPS1-4022PL
3.7
VFPS1-4037PL
5.5
VFPS1-4055PL
7.5
VFPS1-4075PL
11
VFPS1-4110PL
15
VFPS1-4150PL
18.5
VFPS1-4185PL
22
VFPS1-4220PL
30
VFPS1-4300PL
37
VFPS1-4370PL
45
VFPS1-4450PL
55
VFPS1-4550PL
75
VFPS1-4750PL
90
VFPS1-4900PC
110
VFPS1-4110KPC
400V
class
132
VFPS1-4132KPC
160
VFPS1-4160KPC
220
VFPS1-4220KPC
250
VFPS1-4250KPC
280
VFPS1-4280KPC
315
VFPS1-4315KPC
400
VFPS1-4400KPC
500
VFPS1-4500KPC
630
VFPS1-4630KPC
(*1): Model in square brackets is fitted with top cover.
(*2): To use a 400V/250kW inverter or larger in combination with an external braking resistor (DGP600 series), a braking unit (PB7) with a built-in braking
resistor drive circuit is also needed.
(*3): The options are selected based on the premise that 600V HIV insulated wires (continuous allowable temperature: 75°C) are used.
(*4): Each MSF-****Z model is composed of a reactor, a resistor and a capacitor, and as a guide, use a cable 300m or less in length to connect the
inverter to the motor.
Each SWF-****K model is an output-dedicated surge suppression reactor, and as a guide, use a cable 100m or less in length.
(*5): These reactors are usable for each of 200V class and 400V class.
(*6): Be sure to connect DC reactor to 200V-55kW and above models and 400V-90kW and above models. (Not necessary for DC power input.)
When a 200V-55kW and above models or 400V-90 to 280kW models is replaced with new one, the reactor (model: DCL-****) used with the current
inverter can be used as-is with the new inverter. In such cases, therefore, you do not need to purchase any reactors in this table.
(*7): In case of using the SWF filter, set the parameter  to  or  and set the carrier frequency to 4kHz and above.
Input AC
DC reactor
EMC Diredctive
reactor
(DCL)
compliant noise
(ACL)
(*6)
reduction filter
DCL2-2004
PFL-2005S
DCL2-2007
DCL2-2015
PFL-2011S
DCL2-2022
PFL-2018S
DCL2-2037
PFL-2025S
DCL2-2055
DCL2-2075
PFL-2050S
PFL-2100S
Built in
PFL-2150S
PFL-2200S
PFL-2300S
Attached as
PFL-2400S
standard
PFL-2600S
DCL2-4007
DCL2-4015
PFL-4012S
DCL2-4022
DCL2-4037
DCL2-4055
PFL-4025S
DCL2-4075
DCL2-4110
DCL2-4150
PFL-4050S
PFL-4100S
Built in
PFL-4150S
PFL-4300S
PFL-4400S
PFL-4600S
Attached as
standard
PFL-4800S
PFL-4450S
×2(parallel)
PFL-4613S
×2(parallel)
J-7
Braking resistor
(*1)
PBR-2007
PBR-2002
Built in
PBR-2037
PBR3-2055
PBR3-2075
PBR3-2110
EMF3-4074E
PBR3-2150
EMF3-4090F
PBR3-2220
EMF3-4180H
PBR-222W002
EMF3-4300I
DGP600W-B1
[DGP600W-C1]
EMF3-4600J
PBR-2007
PBR-4037
PBR3-4055
PBR3-4075
PBR3-4110
PBR3-4150
PBR3-4220
PBR-417W008
DGP600W-B2
Built in
[DGP600W-C2]
DGP600W-B3
[DGP600W-C3]
PB7-4200K(*2)
DGP600W-B4
[DGP600W-C4]
PB7-4400K(*2)
DGP600W-B3
×2(parallel)
[DGP600W-C3
×2(parallel)]
PB7-4400K(*2)
DGP600W-B4
×2(parallel)
[DGP600W-C4
×2(parallel)]
E6581386
Motor end
Control
surge voltage
power
suppression
supply
filter
backup
(*4)
MSF-4015Z
MSF-4037Z
MSF-4075Z
MSF-4150Z
CPS002Z
MSF-4220Z
MSF-4370Z
MSF-4550Z
MSF-4750Z
SWF-4160K
(*7)
SWF-4220K
(*7)
SWF-4355K
(*7)
10
SWF-4630K
(*7)