[22] Communication function
Communi
Title
cation
Function
No.

0576
IP address setting method

0577

0578
IP card

0579

0580

0581
0582

Subnet mask
0583

0584

0585

0586

IP gate1
0587

0588


0589

0590
IP master

0591

0592

0593
IO scan permission

0594
Communication time-out (Modbus)
*1:This function is for Etherenet communication option.(planning)
[23] Protection functions [1/4]
Communi
Title
cation
Function
No.
0601
Stall prevention level

0602
Inverter trip record retention selection

0603
Emergency stop

0604
Emergency DC braking control time

Output phase failure detection mode

0605
selection
Adjustment range
0: Manual setting (~ Enabled)
1: BOOTP
2: DHCP
Data1
0~255
Data2
0~255
Data3
0~255
Data4
0~255
Data1
0~255
Data2
0~255
Data3
0~255
Data4
0~255
Data1
0~255
Data2
0~255
Data3
0~255
Data4
0~255
Data1
0~255
Data2
0~255
Data3
0~255
Data4
0~255
0: Prohibit
1: Permit
0.0~60.0sec.
Adjustment range
10~164%, 165:Deactivated
0:Clear when power is turned off
1:Retain even after power is turned off
0:Coast stop
1:Deceleration stop
2:Emergency DC braking
0.0~20.0 sec.
0:Deselect
1:At starting (only one time after power is turned
on)
2:At starting (each time power is turned on)
3:During operation
4:At starting + during operation
5:Output cut-off detection enabled
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.1
0
Enabled
●/●
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
120
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.1
1.0
Enabled
●/●
1/1
0
Disabled
●/●
PM
V/f Constant Reference
control
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
PM
V/f Constant Reference
control
6. 26. 1
6. 26. 2
6. 26. 3
6. 26. 3
6. 26. 4

Advertisement

Table of Contents
loading