[27] Communication function [3/5]
Communi
Title
cation
Function
No.
0825
Send waiting time (4-wire RS485)
Inverter-to-inverter communication setting
0826
(4-wire RS485)
0829
Protocol selection (4-wire RS485)
0830
Communication option setting 1
0831
Communication option setting 2
0832
Communication option setting 3
0833
Communication option setting 4
0834
Communication option setting 5
0835
Communication option setting 6
0836
Communication option setting 7
0837
Communication option setting 8
0838
Communication option setting 9
0841
Communication option setting 10
0842
Communication option setting 11
0843
Communication option setting 12
0844
Communication option setting 13
0845
Communication option setting 14
0846
Communication option setting 15
0847
Communication option setting 16
0848
Communication option setting 17
Communication2 time-out
0849
condition selection
0850
Disconnection detection extended time
0851
Inverter operation at disconnection
0852
Preset speed operation selection
*1: For details, refer to Instruction Manual (E6581281, E6581343) specified in Section 6.36.
Adjustment range
0.00:Default, 0.01~2.00 sec.
0:Slave (issues a 0Hz command if something goes
wrong with the master)
1:Slave (continues operation if something goes
wrong with the master)
2:Slave (trips for emergency stop if something
goes wrong with the master)
3:Master (sends a frequency command)
4:Master (sends an output frequency)
5: -
6: -
0:TOSHIBA
1:MODBUS
0~7
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0000~
0:Disconnection detection
1:When communication mode enable
2:1+Driving operation
0.0~100.0 sec.
0:Inverter stop, communication command,
frequency mode open (by , )
1:None (continued operation)
2:Deceleration stop
3:Coast stop
4:Network error ( trip)
5:Preset speed operation (by setting)
0:None
1~15:Preset speed operation (by parameter
setting)
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
0.01/0.01
0.00
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0000
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
PM
V/f Constant Reference
control
●
●
6. 34. 1
●
●
6. 34. 1
●
●
6. 34. 1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1
●
●
*1