[16] PID control [2/2]
Communi
Title
cation
Function
No.

0365
PID deviation lower limit

0366
Differential (D) gain
0367
Process upper limit


0368
Process lower limit

0369
PID control waiting time
0370
PID output upper limit

0371
PID output lower limit

Process increasing rate (speed type PID
0372

control)
Process decreasing rate (speed type PID

0373
control)
Frequency command agreement detection

0374
range
*1:  For details, refer to Instruction Manual (E6581329) specified in Section 6.36.
*2: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
[17] Speed feedback/positioning control
Communi
Title
cation
Function
No.

0375
Number of PG input pulses

0376
Selection of number of PG input phases

0377
PG disconnection detection
0378
Number of RP terminal input pulses


0379
PID output dead band
*1:  For details, refer to Instruction Manual (E6581319) specified in Section 6.36.
*2:  For details, refer to Instruction Manual (E6581341) specified in Section 6.36.
*3:  For details, refer to Instruction Manual (E6581329) specified in Section 6.36.
Adjustment range
~ Hz
0.00~2.55
~ Hz
~ Hz
0~2400 sec.
~ Hz
~ Hz
0.1~600.0
0.1~600.0
0.0~ Hz
Adjustment range
12~9999
1:Single-phase input
2:Two-phase input
3:Two-phase input (Inversion of polarity)
0:Disabled
1:Enabled (with filter)
2:Enabled (Detection of momentary power failure)
12~9999
0~100%
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
0.1/0.01
*2
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.1/0.01
*2
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.01
*2
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.1
10.0
Enabled
●/●
0.1/0.1
10.0
Enabled
●/●
0.1/0.01
2.5
Enabled
●/●
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
Write during
setting unit
Default
Vector
running
(Panel/Communi
setting
control
cation)
1/1
500
Disabled
-/●
1/1
2
Disabled
-/●
1/1
0
Disabled
-/●
1/1
500
Disabled
●/●
1/1
0
Enabled
●/●
PM
V/f
Reference
control
6. 18 *1
6. 18 *1
6. 18 *1
6. 18 *1
6. 18 *1
6. 18 *1
6. 18 *1
6. 18 *1
6. 18 *1
6. 18 *1
PM
V/f
Reference
control
-
-
*1
-
-
*1
-
-
*1
*2
*3