Toshiba TOSVERT VF-PS1 Instruction Manual page 256

Variable torque inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

[3] Terminal function selection
Communi
Title
cation
Function
No.
0110
Always ON function selection 1

0111
Input terminal function selection 1 (F)


0112
Input terminal function selection 2 (R)

0114
Input terminal function selection 4 (RES)
0115
Input terminal function selection 5 (S1)


0116
Input terminal function selection 6 (S2)

0117
Input terminal function selection 7 (S3)
0118
Input terminal function selection 8 (RR/S4)

0119
Input terminal function selection 9 (LI1)


0120
Input terminal function selection 10 (LI2)

0121
Input terminal selection 11 (LI3)
0122
Input terminal selection 12 (LI4)


0123
Input terminal selection 13 (LI5)

0124
Input terminal selection 14 (LI6)
0125
Input terminal selection 15 (LI7)

0126
Input terminal selection 16 (LI8)


0127
Always ON function selection 2

0128
Always ON function selection 3
0130
Output terminal function selection 1 (OUT1) 0~255 *2


0131
Output terminal function selection 2 (OUT2) 0~255 *2

0132
Output terminal function selection 3 (FL)
0133
Output terminal function selection 4 (OUT3) 0~255 *2

0134
Output terminal function selection 5 (OUT4) 0~255 *2


0135
Output terminal function selection 6 (R1)

0136
Output terminal function selection 7 (OUT5) 0~255 *2
0137
Output terminal function selection 8 (OUT6) 0~255 *2


0138
Output terminal function selection 9 (R2)
*1:  For the adjustment range, see the table on page K-38.
*2:  For the adjustment range, see the table on page K-39.
Adjustment range
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~255 *2
0~255 *2
0~255 *2
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
6
Disabled
●/●
1/1
2
Disabled
●/●
1/1
4
Disabled
●/●
1/1
8
Disabled
●/●
1/1
10
Disabled
●/●
1/1
12
Disabled
●/●
1/1
14
Disabled
●/●
1/1
16
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
4
Disabled
●/●
1/1
6
Disabled
●/●
1/1
10
Disabled
●/●
1/1
254
Disabled
●/●
1/1
254
Disabled
●/●
1/1
254
Disabled
●/●
1/1
254
Disabled
●/●
1/1
254
Disabled
●/●
1/1
254
Disabled
●/●
PM
V/f
Reference
control
6. 3. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
7. 2. 1
6. 3. 1
6. 3. 1
7. 2. 2
7. 2. 2
7. 2. 2
7. 2. 2
7. 2. 2
7. 2. 2
7. 2. 2
7. 2. 2
7. 2. 2

Advertisement

Table of Contents
loading

Table of Contents