5.6

Meter setting and adjustment

 : Meter selection
 : Meter adjustment
For details, see 3.4.
5.7

Forward/reverse run selection (Panel keypad)

 : Forward/reverse run selection (Panel keypad)
• Function
Program the direction of rotation of the motor when the running and stopping are made using the RUN
key and STOP key on the operation panel.
Valid when  (command mode) is set to  (operation panel).
Parameter setting
Title
Forward/reverse run selection

(Panel keypad)
When  is set to , the standard monitor is displayed, pressing the FWD/REV key on the extension
panel (option RKP007Z) changes the direction of rotation from reverse to forward after displaying the
message .
Pressing the FWD/REV key again changes the direction of rotation from reverse to forward after
displaying the message .
Check the direction of rotation on the status monitor. For monitoring, see8.1
: Forward run
: Reverse run
When the F and R terminals are used for switching between forward and reverse rotation from the
terminal board, the  forward/reverse run selection parameter is rendered invalid.
Short across the F-CC terminals: forward rotation
Short across the R-CC terminals: reverse rotation.
The inverter was factory-configured by default so that shorting terminals F-CC and terminals R-CC
simultaneously would cause the motor to slow down to a stop.
Using the parameter , however, you can select between forward run and reverse run.
Function
0: Forward run
1: Reverse run
2: Forward run (F/R switching on
remote keypad)
3: Reverse run (F/R switching on
remote keypad)
E-13
Adjustment range
E6581595
5
Default setting
0