Setting Acceleration/Deceleration Time; Automatic Acceleration/Deceleration - Toshiba TOSVERT VF-PS1 Instruction Manual

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

5.2

Setting acceleration/deceleration time

• Function
1) For acceleration time 1
0Hz to maximum frequency
2) For deceleration time 1
maximum frequency

5.2.1 Automatic acceleration/deceleration

This automatically adjusts acceleration and deceleration time in line with load size.
=
* Adjusts the acceleration/deceleration time automatically within the range of 1/8 to 8 times as long as the
time set with the
=
* Automatically adjusts speed during acceleration only. During deceleration, speed is not adjusted
automatically but reduced at the rate set with
5
Output
frequency [Hz]
Set
[Parameter setting]
Title
When automatically setting acceleration/deceleration time, always change the acceleration/deceleration time so
that it conforms with the load.
The acceleration/deceleration time changes constantly with load fluctuations.
For inverters that requires a fixed acceleration/deceleration time, use the manual settings (
When using a braking resistor or braking unit, do not set the
overloaded.
Use this parameter after actually connecting the motor.
Setting acceleration/deceleration time (
conforms to further changes in load.
When the inverter is used with a load that fluctuates considerably, it may fail to adjust the acceleration or
deceleration time in time, and therefore may be tripped.
: Automatic acceleration/deceleration
: Acceleration time 1
: Deceleration time 1
programs the time that it takes for the inverter output frequency to go from
.
programs the time that it takes for the inverter output frequency to got from
to 0Hz.
or
, depending on the current rating of the inverter.
When load is small
0
Acceleration
Deceleration
Acceleration/deceleration time → decrease
(automatic acceleration/deceleration) to
Function
Automatic acceleration/deceleration
.
Output
When load is large
frequency [Hz]
0
Time [s]
Acceleration
Acceleration/deceleration time → increase
or
Adjustment range
:Disabled (Manual setting)
:Automatic setting
:Automatic setting (during
acceleration only)
= . Or the regenerative braking resistor may be
,
) in conformance with mean load allows optimum setting that
E-2
E6581531
Time [s]
Deceleration
.
Default setting
,
).

Advertisement