Setting Parameters By Operating Method - Toshiba TOSVERT VF-PS1 Instruction Manual

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

5.4

Setting parameters by operating method

: Automatic function setting
• Function
Automatically programs all parameters (parameters described below) related to the functions by
selecting the inverter's operating method.
The major functions can be programmed simply.
[Parameter setting]
Title
Function
Automatic
function setting
Automatically programmed functions and parameter set values
:
Default
Disabled
setting
:Terminal
board
:RR/S4
:Voltage
input
:Standby
:Preset
speed
(S3)
command 3
:
/
terminal
switching
%
:VI/II
⇒ Refer to Section 11 for input terminal functions.
Disabled (
= )
No change is made to the parameter setting.
Frequency setting by means of voltage: (
Operation is performed by applying a voltage for setting the RR/S4 terminal 1 frequency.
When sink logic is selected:
PWR-P24/PLC ON:
F-CC ON:
Forward run
R-CC ON: Reverse run
Frequency setting by means of current
This setting is used to set the frequency by applying a current of 4-20mA to the VI/II terminal.
PWR-P24/PLC ON:
Standby (ON (short-circuited) by default)
F-CC ON:
Forward run
R-CC ON:
Reverse run
Voltage/current switching by means of an external terminal
Switching between remote and local (different frequency commands) can be performed by turning on or off the S3 terminal.
In that case, apply a voltage via the RR/S4 terminal and a current via the VI/II terminal.
S3-CC OFF: The frequency is set according to the voltage applied to the RR/S4 terminal.
S3-CC ON: The frequency is set according to the current applied to the VI/II terminal.
In sink logic mode: PWR-P24/PLC ON: Standby (ON (short-circuited) by default), F-CC ON: Forward run, R-CC ON: Reverse run.
:Disabled
:Frequency setting by means of voltage
:Frequency setting by means of current
:Voltage/current switching from external terminal
:Frequency setting on operation panel and operation by means of terminal
:Frequency setting and operation on operation panel
:Coast stop
:
:
Frequency
Frequency
setting by
setting by
means of
means of current
voltage
:RR/S4
:VI/II
:Current input
:
/
:
/
terminal
terminal
switching
switching
%
:RR/S4
:VI/II
= )
Standby (ON (short-circuited) by default)
Adjustment range
:
:
Voltage/current
Frequency setting
switching from
on operation panel
external terminal
and operation by
means of terminal
:Terminal
board
:Operation
:RR/S4
panel
:Current input
:Frequency
priority switching
:
/
:
/
terminal
terminal
switching
switching
%
:Operation
:VI/II
panel
E-5
E6581531
Default setting
:
:
Frequency
Coast stop
setting and
operation on
operation panel
:Operation
panel
:Operation
panel
:No
function is
assigned
:Standby
:
/
terminal
switching
:Operation
panel
5

Advertisement

Table of Contents
loading

Table of Contents