Toshiba TOSVERT VF-PS1 Instruction Manual page 266

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

[22] Protection functions [3/3]
Communication
Title
Function
No.
Control power supply backup option
0647
failure monitoring
0650
Forced fire-speed control selection
0651
Undertorque detection selection
Undertorque detection level during
0652
power running
Undertorque detection level during
0653
regenerative braking
0654
Undertorque detection time
0655
Undertorque detection hysteresis
Adjustment range
0:Control power supply not backed up
1:Control power supply backed up (alarm in the
event of a failure)
2:Control power supply backed up (tripping in
the event of a failure)
0:Disabled, 1:Enabled
0:Alarm mode, 1:Trip mode
0~250%
0~250%
0.00~10.00 sec.
0~100%
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Default setting
Write
setting unit
during
(Panel/Communi
=
=
=
running
cation)
500V
575V
690V
-50Hz
-60Hz
-50Hz
1/1
0
0
0
Disabled
1/1
0
0
0
Enabled
1/1
0
0
0
Enabled
1/0.01
0
0
0
Enabled
1/0.01
0
0
0
Enabled
0.01/0.01
0.50
0.50
0.50
Enabled
1/0.01
10
10
10
Enabled
Vector
V/f
Reference
control
Constant
●/●
6. 26. 24
●/●
6. 27
●/●
6. 28
●/●
6. 28
●/●
6. 28
●/●
6. 28
●/●
6. 28