8.4.2 Monitor display at tripping

At the occurrence of a trip, the same information as that displayed in the mode described in 8.2.1, "Status monitor
under normal conditions," can be displayed, as shown in the table below, if the inverter is not turned off or reset.
To display trip information after turning off or resetting the inverter, follow the steps described in 8.2.2, "Display of
detailed information a past trip."
Example of call-up of trip information
Commun
ication
Item displayed
No.
FC90
Trip information
-
Setting monitor mode
FE01
Direction of rotation
Frequency command
*1
-
value
[Note 4]
-
Output current
*2
[Note 4]
Input voltage (DC
[Note 5]
-
detection)
*3
[Note 4]
-
Output voltage
*4
FE00
Output frequency
Input terminal
information 1
Input terminal
FE06
information 2
Input terminal
information 3
Output terminal
[Note 6]
information 1
FE07
Output terminal
information 2
FE08
CPU1 version
FE73
CPU2 version
FE10
Past trip 1
[Note 7]
FE11
Past trip 2
[Note 7]
FE12
Past trip 3
[Note 7]
[Note 7]
FE13
Past trip 4
(Continued overleaf)
Key
LED
operated
display
Status monitor mode (The code blinks if a trip occurs.)
The motor coasts and comes to a stop (coast stop).
The first basic parameter "History function (
MODE
displayed.
The direction of rotation when the trip occurred is
MODE
displayed.( :Forward run,
The operation command value when the trip occurred
is displayed.
The inverter output current at tripping (load current) is
displayed.
The inverter DC voltage at the occurrence of a trip is
displayed.
The inverter output voltage at the occurrence of a trip
is displayed.
The operation frequency when the trip occurred is
displayed.
The ON/OFF status of each of the control input
terminals at tripping (F, R, RES, S1, S2, S3, RR/S4) is
displayed in bits.
The ON/OFF status of each of the optional control
input terminals at tripping (LI1, LI2, LI3, LI4) is
displayed in bits.
The ON/OFF status of each of the optional control
input terminals at tripping (LI5, LI6, LI7, LI8) is
displayed in bits.
The ON/OFF status of each of the control output
terminals at tripping (OUT1, OUT2 and FL) is
displayed in bits.
The ON/OFF status of each of the optional control
output terminals (OUT3, OUT4, R1, OUT5, OUT6, R2,
R3, R4) is displayed in bits.
The version of the CPU1 is displayed.
The version of the CPU2 is displayed.
Past trip 1 (displayed alternately at 0.5-sec. intervals)
Past trip 2 (displayed alternately at 0.5-sec. intervals)
Past trip 3 (displayed alternately at 0.5-sec. intervals)
Past trip 4 (displayed alternately at 0.5-sec. intervals)
H-11
E6581531
Description
)" is
:Reverse run)
8

Advertisement