Auto-stop in case of lower-limit frequency continuous operation

(Sleep/Wake-up function)
: Time limit for lower-limit frequency operation
• Function
If operation is carried out continuously at a frequency below the lower-limit frequency (
time set
"
" is always displayed on the operation panel. (Blinking alternately)
The auto-stop function will be disabled when the frequency command value reaches over the lower limit
frequency (
)+0.2Hz or the operation command is turned to off.
[Parameter setting]
Title
Auto-stop in case of lower-limit frequency
continuous operation
Output frequency [Hz]
+0.2Hz
Operation signal (F-CC)
Note: This function is enabled even at the start of operation and during switching between forward and reverse run.
, theinverter will automatically slow down the motor to a stop.
Function
Adjustment range
:None
~
F-17
E6581531
) for the period
Default setting
sec.
Time [s]
ON
OFF
6