[22] Protection functions [1/3]
Communication
Title
Function
No.
0601
Stall prevention level
0602
Inverter trip record retention selection
0603
Emergency stop
0604
Emergency DC braking control time
Output phase failure detection mode
0605
selection
0606
OL reduction starting frequency
Input phase failure detection mode
0608
selection
0609
Low current detection hysteresis width
0610
Low current trip selection
0611
Low current detection current
0612
Low current detection time
Selection of short circuit detection at
0613
starting
0615
Overtorque trip selection
Overtorque detection level during power
0616
running
Overtorque detection level during
0617
regenerative braking
0618
Overtorque detection time
0619
Overtorque detection hysteresis
0620
Cooling fan control selection
0621
Cumulative operation time alarm setting
0622
Abnormal speed detection time
Adjustment range
10~164%, 165:Deactivated
0:Clear when power is turned off
1:Retain even after power is turned off
0:Coast stop
1:Deceleration stop
2:Emergency DC braking
0.0~20.0 sec.
0:Deselect
1:At starting (only one time after power is
turned on)
2:At starting (each time power is turned on)
3:During operation
4:At starting + during operation
5:Output cut-off detection enabled
0.0~60.0Hz
0:Disabled
1:Enabled
1~20%
0:No trip
1:Trip
0~100%
0~255 sec.
0:Each time (standard pulse)
1:Only one time after power is turned on
2:Each time (short pulse)
3.Only one time after power is turn on (short
pulse)
4:Each time (Extremely shot-time pulse)
5.Only one time after power is turn on
(Extremely shot-time pulse)
0:No trip
1:Trip
0~250%
0~250%
0.00~10.00 sec.
0~100%
0:Auto
1:Always ON
0.1~999.9 (x100h)
0.01~100.0 sec.
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Default setting
Write
setting unit
during
(Panel/Communi
=
=
=
running
cation)
500V
575V
690V
-50Hz
-60Hz
-50Hz
1/1
150
150
150
Enabled
1/1
0
0
0
Enabled
1/1
0
0
0
Disabled
0.1/0.1
1.0
1.0
1.0
Enabled
0
0
0
1/1
Disabled
0.1/0.01
6.0
6.0
6.0
Enabled
1/1
1
1
1
Disabled
1/1
10
10
10
Enabled
1/1
0
0
0
Enabled
0
0
0
1/1
Enabled
1/1
0
0
0
Enabled
1/1
0
0
0
Disabled
1/1
0
0
0
Enabled
1/0.01
150
150
150
Enabled
1/0.01
150
150
150
Enabled
0.01/0.01
0.50
0.50
0.50
Enabled
10
10
10
1/0.01
Enabled
1/1
0
0
0
Enabled
0.1/0.1
610.0
610.0
610.0 Enabled
0.01/0.01
0.01
0.01
0.01
Enabled
Vector
V/f
Reference
control
Constant
●/●
6. 26. 1
●/●
6. 26. 3
●/●
6. 26. 4
●/●
6. 26. 4
●/●
6. 26. 5
●/●
5. 14
●/●
6. 26. 7
●/●
6. 26. 8
●/●
6. 26. 8
●/●
6. 26. 8
●/●
6. 26. 8
●/●
6. 26. 9
●/●
6. 26. 10
●/●
6. 26. 10
●/●
6. 26. 10
●/●
6. 26. 10
●/●
6. 26. 10
●/●
6. 26. 11
●/●
6. 26. 12
-/●
-
6. 26. 13