Parameter setting
Positive
Negative
logic
7
Note 1: "ON" in positive logic
"OFF" in positive logic : Open collector output transistor or relay is turned off.
"ON" in negative logic : Open collector output transistor or relay is turned off.
"OFF" in negative logic : Open collector output transistor or relay is turned on.
Note 2: Alarm output check conditions are as follows.
(1) Undervoltage detected :To be checked during operation.
(2) Low current detected : To be checked during operation command.
(3) Overtorque detected : To be checked always.
Function
logic
Specified data output
4
Specified data output
5
Specified data output
6
Specified data output
7
Positive torque limit
Negative torque limit
Output for external
rush suppression relay
L-STOP
Part replacement
alarm
Over-torque pre-alarm
Frequency command
1/2 selection
Failure FL (Except
emergency stop)
Local/remote switching ON: Local mode
Forced operation
(Force)
Forced operation
(Force)
Undertorque detection
Frequency command
agreement signal
(RR/S4)
Frequency command
agreement signal (VI)
Frequency command
agreement signal (RX)
PTC alarm detection
Power removal signal
VI/VII input wire
breakage
My function output 1
My function output 2
My function output 3
My function output 4
My function output 5
My function output 6
My function output 7
My function output 8
My function output 9
My function output 10
My function output 11
My function output 12
My function output 13
My function output 14
My function output 15
My function output 16
Always OFF (for
terminal signal tests)
: Open collector output transistor or relay is turned on.
Operation output specifications (in case of positive logic)
Output of the designated data in 7-bit.
ON:Positive torque is over the positive torque limit level.
ON:Negative torque is over the positive torque limit level.
ON:External rush suppression relay is actuated.
ON:Operation at the lower limit frequency is performed continuously.
Alarm:The time of replacement of parts is approaching.
ON:Over-torque is detected.
ON:Frequency command selection 2 is selected.
ON:A trip other than emergency stop has occurred.
ON: Forced operation (Operation continued in the case of a minor
failure)
ON: Forced operation
ON: If an undertorque is detected
ON: If the frequency command specified with
agrees with the frequency command entered via RR/S4 (when RR is
used as a signal input terminal). An agreement range can be
specified with
.
ON: If the frequency command specified with
agrees with the frequency command entered via VI. An agreement
detection range can be specified with
ON: If the frequency command specified with
agrees with the frequency command entered via RX An agreement
detection range can be specified with
ON: If the PTC thermal specified with
ON: When a PWR input signal is received
ON: If the breakage of a VI/VII input wire is detected
ON:My function output 1 is ON.
ON:My function output 2 is ON.
ON:My function output 3 is ON.
ON:My function output 4 is ON.
ON:My function output 5 is ON.
ON:My function output 6 is ON.
ON:My function output 7 is ON.
ON:My function output 8 is ON.
ON:My function output 9 is ON.
ON:My function output 10 is ON.
ON:My function output 11 is ON.
ON:My function output 12 is ON.
ON:My function output 13 is ON.
ON:My function output 14 is ON.
ON:My function output 15 is ON.
ON:My function output 16 is ON.
Output signal always OFF
G-8
E6581531
or
or
.
or
.
or
is detected