[9] Jogging operation
Communication
Title
Function
No.
0260
Jog run frequency
0261
Jog run stop pattern
0262
Operation panel jog run mode
Input from external contacts - UP
0264
response time
Input from external contacts - UP
0265
frequency step
Input from external contacts - DOWN
0266
response time
Input from external contacts - DOWN
0267
frequency step
0268
Initial UP/DOWN frequency
0269
Initial up/down frequency rewriting
[10] Jump frequency
Communication
Title
Function
No.
0270
Jump frequency 1
0271
Jumping width 1
0272
Jump frequency 2
0273
Jumping width 2
0274
Jump frequency 3
0275
Jumping width 3
[11] Preset speed operation frequency (8~15) [1/2]
Communication
Title
Function
No.
0287
Preset speed operation frequency 8
0288
Preset speed operation frequency 9
0289
Preset speed operation frequency 10
Adjustment range
~20.0Hz
0:Deceleration stop
1:Coast stop
2:DC braking stop
0:Disabled
1:Operation panel jog run mode enabled
0.0~10.0 sec.
0.0~
Hz
0.0~10.0 sec.
0.0~
Hz
~
Hz
0:Not changed
1:Setting of
changed when power is
turned off
Adjustment range
0.0~
Hz
0.0~30.0Hz
0.0~
Hz
0.0~30.0Hz
0.0~
Hz
0.0~30.0Hz
Adjustment range
~
Hz
~
Hz
~
Hz
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Default setting
Write
setting unit
during
(Panel/Communi
=
=
=
running
cation)
500V
575V
690V
-50Hz
-60Hz
-50Hz
5.0
5.0
5.0
0.1/0.01
Enabled
1/1
0
0
0
Disabled
1/1
0
0
0
Enabled
0.1
0.1
0.1
0.1/0.1
Enabled
0.1/0.01
0.1
0.1
0.1
Enabled
0.1/0.1
0.1
0.1
0.1
Enabled
0.1/0.01
0.1
0.1
0.1
Enabled
0.1/0.01
0.0
0.0
0.0
Enabled
1/1
1
1
1
Enabled
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Default setting
Write
setting unit
during
(Panel/Communi
=
=
=
running
cation)
500V
575V
690V
-50Hz
-60Hz
-50Hz
0.0
0.0
0.0
0.1/0.01
Enabled
0.1/0.01
0.0
0.0
0.0
Enabled
0.1/0.01
0.0
0.0
0.0
Enabled
0.1/0.01
0.0
0.0
0.0
Enabled
0.1/0.01
0.0
0.0
0.0
Enabled
0.0
0.0
0.0
0.1/0.01
Enabled
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Default setting
Write
setting unit
during
(Panel/Communi
=
=
=
running
cation)
500V
575V
690V
-50Hz
-60Hz
-50Hz
0.1/0.01
0.0
0.0
0.0
Enabled
0.0
0.0
0.0
0.1/0.01
Enabled
0.1/0.01
0.0
0.0
0.0
Enabled
Vector
V/f
Reference
control
●/●
6. 10
●/●
6. 10
●/●
6. 10
●/●
6. 11
●/●
6. 11
●/●
6. 11
●/●
6. 11
●/●
6. 11
●/●
6. 11
Vector
V/f
Reference
control
●/●
6. 12
●/●
6. 12
●/●
6. 12
●/●
6. 12
●/●
6. 12
●/●
6. 12
Vector
V/f
Reference
control
●/●
5. 12
●/●
5. 12
●/●
5. 12