Toshiba TOSVERT VF-PS1 Instruction Manual page 110

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

500V-50Hz default setting (
Setting
to
causes default value is to be set for 500V-50Hz.
When
to be set after setting
Setting
to
causes all the following parameters to be changed from factory shipment (
• Base frequency 1
• Base frequency voltage 1
. • Upper limit frequency
• VI/II input point 2 frequency
• RR/S4 input point 2 frequency
• Base frequency 2
• RX input point 2 frequency
• AI1 input point 2 frequency
• AI2 input point 2 frequency
•RP/high-speed pulse input point 2 frequency
575V-60Hz default setting(
Setting
to
causes default value is to be set for 575V-60Hz.
When
to be set after setting
• Base frequency 1
• Base frequency voltage 1
. • Upper limit frequency
• VI/II input point 2 frequency
• RR/S4 input point 2 frequency
• Base frequency 2
• RX input point 2 frequency
• AI1 input point 2 frequency
• AI2 input point 2 frequency
•RP/high-speed pulse input point 2 frequency
*1 VFPS1-5 *** : 116% , VFPS1-6 *** : 134%
690V-50Hz default setting(
Setting
to
causes default value is to be set for 690V-50Hz.
When
to be set after setting
Setting
to
causes all the following parameters to be changed from factory shipment (
• Base frequency 1
• Base frequency voltage 1
. • Upper limit frequency
• VI/II input point 2 frequency
• RR/S4 input point 2 frequency
• Base frequency 2
• RX input point 2 frequency
• AI1 input point 2 frequency
• AI2 input point 2 frequency
•RP/high-speed pulse input point 2 frequency
=
)
default value is to be set for 500V-50Hz (same value as
: 50Hz
•Commercial power/inverter switching frequency
: 500V
• PID deviation upper limit
: 50Hz
• PID deviation lower limit
: 50Hz
• Process upper limit
: 50Hz
• PID output upper limit
: 50Hz
• Motor rated rotational speed
: 50Hz
• Undervoltage detection level
: 50Hz
• Overvoltage limit operation level
: 50Hz
• Point 2 frequency
: 50Hz
=
)
default value is to be set for 575V-60Hz (same value as
: 60Hz
•Commercial power/inverter switching frequency
: 575V
• PID deviation upper limit
: 60Hz
• PID deviation lower limit
: 60Hz
• Process upper limit
: 60Hz
• PID output upper limit
: 60Hz
• Motor rated rotational speed
: 60Hz
• Undervoltage detection level
: 60Hz
• Overvoltage limit operation level
: 60Hz
• Point 2 frequency
: 60Hz
=
)
default value is to be set for 690V-50Hz (same value as
: 60Hz
•Commercial power/inverter switching frequency
: 690V
• PID deviation upper limit
: 50Hz
• PID deviation lower limit
: 50Hz
• Process upper limit
: 50Hz
• PID output upper limit
: 50Hz
• Motor rated rotational speed
: 50Hz
• Undervoltage detection level
: 50Hz
• Overvoltage limit operation level
: 50Hz
• Point 2 frequency
: 50Hz
E-41
E6581531
)
setting)
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
:1400~1480min-1 (According to model)
: 66%
:134%
: 50Hz
)
: 60Hz
: 60Hz
: 60Hz
: 60Hz
: 60Hz
:1680~1775min-1 (According to model)
: 66%
:116% *1
: 60Hz
)
setting)
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
:1400~1480min-1 (According to model)
: 59%
:113%
: 50Hz
5