Toshiba TOSVERT VF-PS1 Instruction Manual page 251

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

[3] Terminal function selection
Communication
Title
No.
0110
Always ON function selection 1
0111
Input terminal function selection 1 (F)
0112
Input terminal function selection 2 (R)
0114
Input terminal function selection 4 (RES) 0~135 *1
0115
Input terminal function selection 5 (S1)
0116
Input terminal function selection 6 (S2)
0117
Input terminal function selection 7 (S3)
Input terminal function selection 8
0118
(RR/S4)
0119
Input terminal function selection 9 (LI1)
0120
Input terminal function selection 10 (LI2)
0121
Input terminal selection 11 (LI3)
0122
Input terminal selection 12 (LI4)
0123
Input terminal selection 13 (LI5)
0124
Input terminal selection 14 (LI6)
0125
Input terminal selection 15 (LI7)
0126
Input terminal selection 16 (LI8)
0127
Always ON function selection 2
0128
Always ON function selection 3
Output terminal function selection 1
0130
(OUT1)
Output terminal function selection 2
0131
(OUT2)
0132
Output terminal function selection 3 (FL)
Output terminal function selection 4
0133
(OUT3)
Output terminal function selection 5
0134
(OUT4)
0135
Output terminal function selection 6 (R1) 0~255 *2
Output terminal function selection 7
0136
(OUT5)
Output terminal function selection 8
0137
(OUT6)
0138
Output terminal function selection 9 (R2) 0~255 *2
*1: ⇒ For the adjustment range, see the table on page K-42.
*2: ⇒ For the adjustment range, see the table on page K-44.
Function
Adjustment range
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~135 *1
0~255 *2
0~255 *2
0~255 *2
0~255 *2
0~255 *2
0~255 *2
0~255 *2
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Default setting
Write
setting unit
during
(Panel/Communi
=
=
=
running
cation)
500V
575V
690V
-50Hz
-60Hz
-50Hz
6
6
6
1/1
Disabled
1/1
2
2
2
Disabled
1/1
4
4
4
Disabled
1/1
8
8
8
Disabled
1/1
10
10
10
Disabled
12
12
12
1/1
Disabled
1/1
14
14
14
Disabled
1/1
16
16
16
Disabled
1/1
0
0
0
Disabled
1/1
0
0
0
Disabled
0
0
0
1/1
Disabled
1/1
0
0
0
Disabled
1/1
0
0
0
Disabled
1/1
0
0
0
Disabled
1/1
0
0
0
Disabled
0
0
0
1/1
Disabled
1/1
0
0
0
Disabled
1/1
0
0
0
Disabled
4
4
4
1/1
Disabled
1/1
6
6
6
Disabled
10
10
10
1/1
Disabled
1/1
254
254
254
Disabled
1/1
254
254
254
Disabled
1/1
254
254
254
Disabled
1/1
254
254
254
Disabled
1/1
254
254
254
Disabled
254
254
254
1/1
Disabled
Vector
V/f
Reference
control
●/●
6. 3. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
7. 2. 1
●/●
6. 3. 1
●/●
6. 3. 1
●/●
7. 2. 2
●/●
7. 2. 2
●/●
7. 2. 2
●/●
7. 2. 2
●/●
7. 2. 2
●/●
7. 2. 2
●/●
7. 2. 2
●/●
7. 2. 2
●/●
7. 2. 2

Advertisement

Table of Contents
loading

Table of Contents