Motor Shaft Fixing Control - Toshiba TOSVERT VF-PS1 Instruction Manual

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

[Priority to DC braking during forward/reverse operation] (Forward/reverse run DC braking priority control
= [Enabled])
  
Output frequency [Hz]
Set frequency
0
Reference frequency
0
Forward run signal (F-CC)
Reverse run signal (R-CC)
(4) During normal forward/reverse run (
(5) If a reverse run (or forward) command is entered during forward run (or reverse) (
(6) If an operation command is entered during DC braking : RUN command has a priority.
(7) If an operation command is changed from ON to OFF during DC braking, DC braking is discontinued to stop the
operation.

6.8.2 Motor shaft fixing control

: Motor shaft fixing control
• Function
This function is used to prevent the motor from running unexpectedly after the motor is stopped because
it's shaft is not restrained or to preheat the motor.
[Parameter setting]
Title
Motor shaft fixing control
If the motor shaft fixing control parameter
to retain the motor after it has come to a full stop by DC braking. To discontinue motor shaft axis fixing control,
cancel the assignment of the input terminal function "ST standby command (6)" to an input terminal. Note, however, that
this function doesn't operate after a DC braking command is entered by control input terminal signal.
When assigning the ST function to the S3 terminal.
Title
Always ON function selection 1
Input terminal function selection 7 (S3)
=
(4)
= )
Function
is set at
Function
F-15
=
(5)
(6)
: Not recognized as a stop command, so that the DC
braking is not active.
DC braking when the frequency set with
decreases below the reference frequency during
deceleration.
Adjustment range
:Disabled,
:Enabled
, DC braking continue at half a braking rate of that set with
Adjustment range
~
~
E6581531
: DC braking
Time [s]
(7)
ON
OFF
ON
OFF
6
= ) :
Default setting
Default setting