Toshiba TOSVERT VF-PS1 Instruction Manual page 252

High performance inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

[4] Terminal response time setup
Communication
Title
No.
Output terminal function selection 10
0168
(R3) *1
Output terminal function selection 11
0169
(R4) *1
0170
Base frequency 2
0171
Base frequency voltage 2
0172
Manual torque boost 2
0173
Thermal protection level 2
*1: Unsupported option
*2: ⇒ For the adjustment range, see the table on page K-44.
*3: Default values vary depending on the capacity. ⇒ See the table of K-47.
[5] V/f 5-point setting
Communication
Title
No.
0190
V/f 5-point setting VF1 frequency
0191
V/f 5-point setting VF1 voltage
0192
V/f 5-point setting VF2 frequency
0193
V/f 5-point setting VF2 voltage
0194
V/f 5-point setting VF3 frequency
0195
V/f 5-point setting VF3 voltage
0196
V/f 5-point setting VF4 frequency
0197
V/f 5-point setting VF4 voltage
0198
V/f 5-point setting VF5 frequency
0199
V/f 5-point setting VF5 voltage
[6] Speed/torque reference gain/bias setup [1/3]
Communication
Title
No.
0200
Frequency priority selection
0201
VI/II input point 1 setting
0202
VI/II input point 1 frequency
Function
Adjustment range
0~255 *2
0~255 *2
25.0~
Hz
50~990V
0.0~30.0%
10~100%
Function
Adjustment range
0.0~
Hz
0.0~100.0%
0.0~
Hz
0.0~100.0%
0.0~
Hz
0.0~100.0%
0.0~
Hz
0.0~100.0%
0.0~
Hz
0.0~100.0%
Function
Adjustment range
0:
/
terminal function selection 104, 105)
1:
/
(switching with
0~100%
0.0~
Hz
Minimum
setting unit
(Panel/Communi
cation)
1/1
1/1
0.1/0.01
1/0.1
0.1/0.1
1/1
Minimum
setting unit
(Panel/Communi
cation)
0.1/0.01
0.1/0.01
0.1/0.01
0.1/0.01
0.1/0.01
0.1/0.01
0.1/0.01
0.1/0.01
0.1/0.01
0.1/0.01
Minimum
setting unit
(Panel/Communi
cation)
terminal switching (input
1/1
frequency switching
)
1/1
0.1/0.01
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Write
Vector
during
control
=
=
=
running
500V
575V
690V
-50Hz
-60Hz
-50Hz
254
254
254
Disabled
●/●
254
254
254
Disabled
●/●
50.0
60.0
50.0
Disabled
-
500
575
690
Disabled
-
*3
*3
*3
Enabled
-
100
100
100
Enabled
-
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Write
Vector
during
control
=
=
=
running
500V
575V
690V
-50Hz
-60Hz
-50Hz
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
0.0
0.0
0.0
Disabled
-
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Write
Vector
during
control
=
=
=
running
500V
575V
690V
-50Hz
-60Hz
-50Hz
0
0
0
Enabled
●/●
0
0
0
Enabled
●/●
0.0
0.0
0.0
Enabled
●/●
V/f
Reference
7. 2. 2
7. 2. 2
6. 4. 1
6. 4. 1
6. 4. 1
6. 4. 1
V/f
Reference
5. 6
5. 6
5. 6
5. 6
5. 6
5. 6
5. 6
5. 6
5. 6
5. 6
V/f
Reference
6. 6. 1
7. 3. 2
7. 3. 2

Advertisement

Table of Contents
loading