Maintenance
item No.
Setting the adjustment of the motor speed
U053
Description
Performs fine adjustment of the speeds of the motors.
Purpose
Basically, the setting need not be changed.
Modify settings by interlock setting only if faulty images occur.
Method
1. Press the OK key.
2. Select the item to be adjusted.
3. Press the OK key.
Display
Set Motor1
Set Motor2
Set Motor3
Set Motor4
Set Motor5
Set Motor6
Setting: [Set Motor1]
1. Select the item to be adjusted.
Display
Drum C(Full)
Drum M(Full)
Drum Y(Full)
Drum K(Full)
Drum C(Half)
Drum M(Half)
Drum Y(Half)
Drum K(Half)
Setting: [Set Motor2]
1. Select the item to be adjusted.
Display
Dev K
Dev CMY
TC(Full)
TC(Half)
Polygon(Full)
Mid Roller
Regist
Description
Description
Adjustment of drum motor M, C, Y, K speeds
Adjustment of developing motor K, developing motor MCY, transfer
motor, polygon motor, middle motor and registration motor speeds
Adjustment of MP motor, eject motor, feedshift motor, fuser motor and
duplex motor speeds
Drum motor K speed adjustment in black/white mode
Adjustment of developing motor K, transfer motor, polygon motor,
middle motor and registration motor speeds in black/white mode
Adjustment of MP motor, eject motor, feedshift motor, fuser motor and
duplex motor speeds in black/white mode
Description
Drum motor C (DRM-C) full speed
Drum motor M (DRM-M) full speed
Drum motor Y (DRM-Y) full speed
Drum motor K (DRM-K) full speed
Drum motor C (DRM-C) half speed
Drum motor M (DRM-M) half speed
Drum motor Y (DRM-Y) half speed
Drum motor K (DRM-K) half speed
Description
Developing motor K (DEVM-K)
Developing motor MCY (DEVM-MCY)
Transfer motor (TRM) full speed
Transfer motor (TRM) half speed
Polygon motor (PM) full speed
Middle motor (MM)
Registration motor (RM)
Setting range
Initial setting
-500 to 500
9
-500 to 500
9
-500 to 500
9
-500 to 500
9
-500 to 500
47
-500 to 500
47
-500 to 500
47
-500 to 500
47
Setting range
Initial setting
-500 to 500
0
-500 to 500
0
-500 to 500
0
-500 to 500
0
-500 to 500
0
-500 to 500
0
-500 to 500
0
2KA
1-3-31